schliessen

Filtern

 

Bibliotheken

Enhanced detection of right-to-left shunt through patent foramen ovale by transthoracic contrast echocardiography using harmonic imaging

When the results of transesophageal echocardiography was regarded as the gold standard for detecting a patent foramen ovale (PFO) in 136 consecutive patients referred for evaluation of cardiac source of embolism, transthoracic harmonic imaging using saline contrast was superior to fundamental imagin... Full description

Journal Title: The American journal of cardiology 2001, Vol.87 (5), p.669-671
Main Author: Ha, Jong-Won
Other Authors: Shin, Mi-Seung , Kang, Seokmin , Pyun, Wook-Bum , Jang, Kil-Jin , Byun, Ki-Hyun , Rim, Se-Joong , Huh, Jihoe , Lee, Byung-In , Chung, Namsik
Format: Electronic Article Electronic Article
Language: English
Subjects:
Quelle: Alma/SFX Local Collection
Publisher: New York, NY: Elsevier Inc
ID: ISSN: 0002-9149
Zum Text:
SendSend as email Add to Book BagAdd to Book Bag
Staff View
recordid: cdi_proquest_miscellaneous_76960130
title: Enhanced detection of right-to-left shunt through patent foramen ovale by transthoracic contrast echocardiography using harmonic imaging
format: Article
creator:
  • Ha, Jong-Won
  • Shin, Mi-Seung
  • Kang, Seokmin
  • Pyun, Wook-Bum
  • Jang, Kil-Jin
  • Byun, Ki-Hyun
  • Rim, Se-Joong
  • Huh, Jihoe
  • Lee, Byung-In
  • Chung, Namsik
subjects:
  • Adult
  • Aged
  • Aged, 80 and over
  • Biological and medical sciences
  • Cardiology
  • Cardiology. Vascular system
  • Cardiovascular disease
  • Congenital heart diseases. Malformations of the aorta, pulmonary vessels and vena cava
  • Echocardiography
  • Echocardiography, Transesophageal
  • Embolism, Paradoxical - diagnostic imaging
  • Female
  • Heart
  • Heart Septal Defects, Atrial - diagnostic imaging
  • Humans
  • Image Enhancement
  • Male
  • Medical sciences
  • Middle Aged
  • Predictive Value of Tests
  • Ultrasonic imaging
ispartof: The American journal of cardiology, 2001, Vol.87 (5), p.669-671
description: When the results of transesophageal echocardiography was regarded as the gold standard for detecting a patent foramen ovale (PFO) in 136 consecutive patients referred for evaluation of cardiac source of embolism, transthoracic harmonic imaging using saline contrast was superior to fundamental imaging in accuracy for detecting a PFO (sensitivity, 22.5%; specificity [p < 0.05] and sensitivity, 100%; specificity 100%, respectively.)
language: eng
source: Alma/SFX Local Collection
identifier: ISSN: 0002-9149
fulltext: fulltext
issn:
  • 0002-9149
  • 1879-1913
url: Link


@attributes
NO1
SEARCH_ENGINEprimo_central_multiple_fe
SEARCH_ENGINE_TYPEPrimo Central Search Engine
RANK2.1752827
LOCALfalse
PrimoNMBib
record
control
sourceidproquest_cross
recordidTN_cdi_proquest_miscellaneous_76960130
sourceformatXML
sourcesystemPC
sourcerecordid69355243
originalsourceidFETCH-LOGICAL-c407t-6c69968a022da3191781c3cdd4d03f448d014bd0701266cbfb56fa19e064a0d53
addsrcrecordideNqFkl1rFTEQhoMo9rT6E5SgIPVidbIf2Q29ECn1AwpeqNchm2R3U_YkxyRbOP_An-1sz6FCb3oVZnhmMvO-Q8grBh8YMP7xJwCUhWC1OAd4D6xumqJ9Qjasa0XBBKueks09ckJOU7rBkLGGPycnjJUVdLzekL9XflJeW0ONzVZnFzwNA41unHKRQzHbIdM0LT7TPMWwjBPdqWwxHEJUW4v0rZot7fc0R-VTnjCtnaY6eEykTK2eglbRuDBGtZv2dEnOj3RScRs8gm6rRky8IM8GNSf78viekd9frn5dfiuuf3z9fvn5utA1tLngmgvBOwVlaVSFe7Yd05U2pjZQDXXdGZSiN9ACKznX_dA3fFBMWOC1AtNUZ-Tdoe8uhj-LTVluXdJ2npW3YUmy5YIDqwDBNw_Am7BEj7NJFK_irGnXbs0B0jGkFO0gdxEXinvJQK4-yTuf5GqCBJB3PskW614fmy_91pr_VUdjEHh7BFTSah5QW-3SPdcJwbr1-4sH32uX1Woiau_mR4f4dKi2qPets1Em7ex6DC7iKUgT3CMd_gE0McNM
sourcetypeAggregation Database
isCDItrue
recordtypearticle
pqid230361575
display
typearticle
titleEnhanced detection of right-to-left shunt through patent foramen ovale by transthoracic contrast echocardiography using harmonic imaging
sourceAlma/SFX Local Collection
creatorHa, Jong-Won ; Shin, Mi-Seung ; Kang, Seokmin ; Pyun, Wook-Bum ; Jang, Kil-Jin ; Byun, Ki-Hyun ; Rim, Se-Joong ; Huh, Jihoe ; Lee, Byung-In ; Chung, Namsik
creatorcontribHa, Jong-Won ; Shin, Mi-Seung ; Kang, Seokmin ; Pyun, Wook-Bum ; Jang, Kil-Jin ; Byun, Ki-Hyun ; Rim, Se-Joong ; Huh, Jihoe ; Lee, Byung-In ; Chung, Namsik
descriptionWhen the results of transesophageal echocardiography was regarded as the gold standard for detecting a patent foramen ovale (PFO) in 136 consecutive patients referred for evaluation of cardiac source of embolism, transthoracic harmonic imaging using saline contrast was superior to fundamental imaging in accuracy for detecting a PFO (sensitivity, 22.5%; specificity [p < 0.05] and sensitivity, 100%; specificity 100%, respectively.)
identifier
0ISSN: 0002-9149
1EISSN: 1879-1913
2DOI: 10.1016/S0002-9149(00)01455-7
3PMID: 11230864
4CODEN: AJCDAG
languageeng
publisherNew York, NY: Elsevier Inc
subjectAdult ; Aged ; Aged, 80 and over ; Biological and medical sciences ; Cardiology ; Cardiology. Vascular system ; Cardiovascular disease ; Congenital heart diseases. Malformations of the aorta, pulmonary vessels and vena cava ; Echocardiography ; Echocardiography, Transesophageal ; Embolism, Paradoxical - diagnostic imaging ; Female ; Heart ; Heart Septal Defects, Atrial - diagnostic imaging ; Humans ; Image Enhancement ; Male ; Medical sciences ; Middle Aged ; Predictive Value of Tests ; Ultrasonic imaging
ispartofThe American journal of cardiology, 2001, Vol.87 (5), p.669-671
rights
02001 Excerpta Medica Inc.
12001 INIST-CNRS
2Copyright Elsevier Sequoia S.A. Mar 1, 2001
lds50peer_reviewed
citedbyFETCH-LOGICAL-c407t-6c69968a022da3191781c3cdd4d03f448d014bd0701266cbfb56fa19e064a0d53
citesFETCH-LOGICAL-c407t-6c69968a022da3191781c3cdd4d03f448d014bd0701266cbfb56fa19e064a0d53
links
openurl$$Topenurl_article
openurlfulltext$$Topenurlfull_article
thumbnail$$Usyndetics_thumb_exl
backlink
0$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=899185$$DView record in Pascal Francis
1$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11230864$$D View this record in MEDLINE/PubMed
search
creatorcontrib
0Ha, Jong-Won
1Shin, Mi-Seung
2Kang, Seokmin
3Pyun, Wook-Bum
4Jang, Kil-Jin
5Byun, Ki-Hyun
6Rim, Se-Joong
7Huh, Jihoe
8Lee, Byung-In
9Chung, Namsik
title
0Enhanced detection of right-to-left shunt through patent foramen ovale by transthoracic contrast echocardiography using harmonic imaging
1The American journal of cardiology
addtitleAm J Cardiol
descriptionWhen the results of transesophageal echocardiography was regarded as the gold standard for detecting a patent foramen ovale (PFO) in 136 consecutive patients referred for evaluation of cardiac source of embolism, transthoracic harmonic imaging using saline contrast was superior to fundamental imaging in accuracy for detecting a PFO (sensitivity, 22.5%; specificity [p < 0.05] and sensitivity, 100%; specificity 100%, respectively.)
subject
0Adult
1Aged
2Aged, 80 and over
3Biological and medical sciences
4Cardiology
5Cardiology. Vascular system
6Cardiovascular disease
7Congenital heart diseases. Malformations of the aorta, pulmonary vessels and vena cava
8Echocardiography
9Echocardiography, Transesophageal
10Embolism, Paradoxical - diagnostic imaging
11Female
12Heart
13Heart Septal Defects, Atrial - diagnostic imaging
14Humans
15Image Enhancement
16Male
17Medical sciences
18Middle Aged
19Predictive Value of Tests
20Ultrasonic imaging
issn
00002-9149
11879-1913
fulltexttrue
rsrctypearticle
creationdate2001
recordtypearticle
recordideNqFkl1rFTEQhoMo9rT6E5SgIPVidbIf2Q29ECn1AwpeqNchm2R3U_YkxyRbOP_An-1sz6FCb3oVZnhmMvO-Q8grBh8YMP7xJwCUhWC1OAd4D6xumqJ9Qjasa0XBBKueks09ckJOU7rBkLGGPycnjJUVdLzekL9XflJeW0ONzVZnFzwNA41unHKRQzHbIdM0LT7TPMWwjBPdqWwxHEJUW4v0rZot7fc0R-VTnjCtnaY6eEykTK2eglbRuDBGtZv2dEnOj3RScRs8gm6rRky8IM8GNSf78viekd9frn5dfiuuf3z9fvn5utA1tLngmgvBOwVlaVSFe7Yd05U2pjZQDXXdGZSiN9ACKznX_dA3fFBMWOC1AtNUZ-Tdoe8uhj-LTVluXdJ2npW3YUmy5YIDqwDBNw_Am7BEj7NJFK_irGnXbs0B0jGkFO0gdxEXinvJQK4-yTuf5GqCBJB3PskW614fmy_91pr_VUdjEHh7BFTSah5QW-3SPdcJwbr1-4sH32uX1Woiau_mR4f4dKi2qPets1Em7ex6DC7iKUgT3CMd_gE0McNM
startdate20010301
enddate20010301
creator
0Ha, Jong-Won
1Shin, Mi-Seung
2Kang, Seokmin
3Pyun, Wook-Bum
4Jang, Kil-Jin
5Byun, Ki-Hyun
6Rim, Se-Joong
7Huh, Jihoe
8Lee, Byung-In
9Chung, Namsik
general
0Elsevier Inc
1Elsevier
2Elsevier Limited
scope
0IQODW
1CGR
2CUY
3CVF
4ECM
5EIF
6NPM
7AAYXX
8CITATION
97QO
107TS
118FD
12FR3
13K9.
14P64
157X8
sort
creationdate20010301
titleEnhanced detection of right-to-left shunt through patent foramen ovale by transthoracic contrast echocardiography using harmonic imaging
authorHa, Jong-Won ; Shin, Mi-Seung ; Kang, Seokmin ; Pyun, Wook-Bum ; Jang, Kil-Jin ; Byun, Ki-Hyun ; Rim, Se-Joong ; Huh, Jihoe ; Lee, Byung-In ; Chung, Namsik
facets
frbrtype5
frbrgroupidcdi_FETCH-LOGICAL-c407t-6c69968a022da3191781c3cdd4d03f448d014bd0701266cbfb56fa19e064a0d53
rsrctypearticles
prefilterarticles
languageeng
creationdate2001
topic
0Adult
1Aged
2Aged, 80 and over
3Biological and medical sciences
4Cardiology
5Cardiology. Vascular system
6Cardiovascular disease
7Congenital heart diseases. Malformations of the aorta, pulmonary vessels and vena cava
8Echocardiography
9Echocardiography, Transesophageal
10Embolism, Paradoxical - diagnostic imaging
11Female
12Heart
13Heart Septal Defects, Atrial - diagnostic imaging
14Humans
15Image Enhancement
16Male
17Medical sciences
18Middle Aged
19Predictive Value of Tests
20Ultrasonic imaging
toplevel
0peer_reviewed
1online_resources
creatorcontrib
0Ha, Jong-Won
1Shin, Mi-Seung
2Kang, Seokmin
3Pyun, Wook-Bum
4Jang, Kil-Jin
5Byun, Ki-Hyun
6Rim, Se-Joong
7Huh, Jihoe
8Lee, Byung-In
9Chung, Namsik
collection
0Pascal-Francis
1Medline
2MEDLINE
3MEDLINE (Ovid)
4MEDLINE
5MEDLINE
6PubMed
7CrossRef
8Biotechnology Research Abstracts
9Physical Education Index
10Technology Research Database
11Engineering Research Database
12ProQuest Health & Medical Complete (Alumni)
13Biotechnology and BioEngineering Abstracts
14MEDLINE - Academic
jtitleThe American journal of cardiology
delivery
delcategoryRemote Search Resource
fulltextfulltext
addata
au
0Ha, Jong-Won
1Shin, Mi-Seung
2Kang, Seokmin
3Pyun, Wook-Bum
4Jang, Kil-Jin
5Byun, Ki-Hyun
6Rim, Se-Joong
7Huh, Jihoe
8Lee, Byung-In
9Chung, Namsik
formatjournal
genrearticle
ristypeJOUR
atitleEnhanced detection of right-to-left shunt through patent foramen ovale by transthoracic contrast echocardiography using harmonic imaging
jtitleThe American journal of cardiology
addtitleAm J Cardiol
date2001-03-01
risdate2001
volume87
issue5
spage669
epage671
pages669-671
issn0002-9149
eissn1879-1913
codenAJCDAG
abstractWhen the results of transesophageal echocardiography was regarded as the gold standard for detecting a patent foramen ovale (PFO) in 136 consecutive patients referred for evaluation of cardiac source of embolism, transthoracic harmonic imaging using saline contrast was superior to fundamental imaging in accuracy for detecting a PFO (sensitivity, 22.5%; specificity [p < 0.05] and sensitivity, 100%; specificity 100%, respectively.)
copNew York, NY
pubElsevier Inc
pmid11230864
doi10.1016/S0002-9149(00)01455-7