Phosphate end dialysis value: a misleading parameter of hemodialysis efficiency. French Society for Pediatric Nephrology

Despite low end dialysis serum phosphate levels (Pe) the control of phosphate retention remains often unsatisfactory in dialyzed patients. In order to assess the value of Pe in dialyzed children as an indicator of dialytic phosphate removal, we studied serum phosphate kinetics over the period of dia... Full description

Journal Title: Pediatric nephrology (Berlin West), 1997-04, Vol.11 (2), p.193-195
Main Author: Fischbach, M
Other Authors: Boudailliez, B , Foulard, M
Format: Electronic Article Electronic Article
Language: English
Subjects:
Publisher: Germany
ID: ISSN: 0931-041X
Link: https://www.ncbi.nlm.nih.gov/pubmed/9090662
Zum Text:
SendSend as email Add to Book BagAdd to Book Bag
Staff View
recordid: cdi_proquest_miscellaneous_78899318
title: Phosphate end dialysis value: a misleading parameter of hemodialysis efficiency. French Society for Pediatric Nephrology
format: Article
creator:
  • Fischbach, M
  • Boudailliez, B
  • Foulard, M
subjects:
  • Adolescent
  • Child
  • Child, Preschool
  • Female
  • France
  • Humans
  • Infant
  • Kidney Failure, Chronic - metabolism
  • Kidney Failure, Chronic - therapy
  • Kidney Failure, Chronic - urine
  • Kinetics
  • Male
  • Phosphates - metabolism
  • Phosphates - urine
  • Renal Dialysis
  • Urea - urine
ispartof: Pediatric nephrology (Berlin, West), 1997-04, Vol.11 (2), p.193-195
description: Despite low end dialysis serum phosphate levels (Pe) the control of phosphate retention remains often unsatisfactory in dialyzed patients. In order to assess the value of Pe in dialyzed children as an indicator of dialytic phosphate removal, we studied serum phosphate kinetics over the period of dialysis and post dialysis and compared these with urea kinetics. A multicenter study was conducted in the 21 French pediatric hemodialysis units and included 144 children under 15 years of age. Blood urea and phosphate concentrations were measured at the beginning, at 45 min later, at the end of dialysis, and 30 min post dialysis. At 60 min and at 360 min post dialysis measurements were made only for a subgroup of 12 children. From the serum levels, reduction ratios for urea (URR) and phosphate (PRR) and post dialysis rebound for urea (PDUR) and phosphate (PDPR) were calculated. URR (over the dialysis session, 72% +/- 9%) was higher than PRR (47% +/- 12%). Moreover, urea removal continued throughout the dialysis period, while most of the reduction in phosphate occurred in the initial dialysis period. Post dialysis urea rebound was limited to the 60th min post dialysis, whereas post dialysis phosphate rebound occurred until the 360th min post dialysis; by this time the serum phosphate levels had almost reached the predialysis levels. In summary, serum phosphate kinetics over dialysis and post dialysis periods in children appear to be misleading for the quantification of phosphate removal, i.e., phosphate clearance is a poor indicator of dialytic phosphate removal.
language: eng
source:
identifier: ISSN: 0931-041X
fulltext: no_fulltext
issn:
  • 0931-041X
  • 1432-198X
url: Link


@attributes
NO1
SEARCH_ENGINEprimo_central_multiple_fe
SEARCH_ENGINE_TYPEPrimo Central Search Engine
RANK1.6605443
LOCALfalse
PrimoNMBib
record
control
sourceidproquest_pubme
recordidTN_cdi_proquest_miscellaneous_78899318
sourceformatXML
sourcesystemPC
sourcerecordid78899318
originalsourceidFETCH-LOGICAL-p532-9108bebdc8435ba38e6b4c1a71ebda872d23ff61c2840418d5a3cb9c9b796cdf0
addsrcrecordideNo9kF1LwzAYhYMoc05_gpAr7ypJPxPvZDgVhg7cxe5KPt6skbapSSv23xtweHXg8HDgOWdoSfMsTShnh3O0JDyjCcnp4RJdhfBJCGEFKxdowQknZZku0c-ucWFoxAgYeo21Fe0cbMDfop3gAQvc2dCC0LY_4kF40cEIHjuDG-jcPw3GWGWhV_M93viYDf5wsRhnbJzHO4jk6K3CbzA03rXuOF-jCyPaADenXKH95mm_fkm278-v68dtMhTRg1PCJEitWJ4VUmQMSpkrKioaS8GqVKeZMSVVKcujJ9OFyJTkisuKl0obskJ3f7ODd18ThLGOQgraVvTgplBXjPF4Eovg7QmcZAe6HrzthJ_r01PkF1GSaLc
sourcetypeAggregation Database
isCDItrue
recordtypearticle
pqid78899318
display
typearticle
titlePhosphate end dialysis value: a misleading parameter of hemodialysis efficiency. French Society for Pediatric Nephrology
creatorFischbach, M ; Boudailliez, B ; Foulard, M
creatorcontribFischbach, M ; Boudailliez, B ; Foulard, M
descriptionDespite low end dialysis serum phosphate levels (Pe) the control of phosphate retention remains often unsatisfactory in dialyzed patients. In order to assess the value of Pe in dialyzed children as an indicator of dialytic phosphate removal, we studied serum phosphate kinetics over the period of dialysis and post dialysis and compared these with urea kinetics. A multicenter study was conducted in the 21 French pediatric hemodialysis units and included 144 children under 15 years of age. Blood urea and phosphate concentrations were measured at the beginning, at 45 min later, at the end of dialysis, and 30 min post dialysis. At 60 min and at 360 min post dialysis measurements were made only for a subgroup of 12 children. From the serum levels, reduction ratios for urea (URR) and phosphate (PRR) and post dialysis rebound for urea (PDUR) and phosphate (PDPR) were calculated. URR (over the dialysis session, 72% +/- 9%) was higher than PRR (47% +/- 12%). Moreover, urea removal continued throughout the dialysis period, while most of the reduction in phosphate occurred in the initial dialysis period. Post dialysis urea rebound was limited to the 60th min post dialysis, whereas post dialysis phosphate rebound occurred until the 360th min post dialysis; by this time the serum phosphate levels had almost reached the predialysis levels. In summary, serum phosphate kinetics over dialysis and post dialysis periods in children appear to be misleading for the quantification of phosphate removal, i.e., phosphate clearance is a poor indicator of dialytic phosphate removal.
identifier
0ISSN: 0931-041X
1EISSN: 1432-198X
2PMID: 9090662
languageeng
publisherGermany
subjectAdolescent ; Child ; Child, Preschool ; Female ; France ; Humans ; Infant ; Kidney Failure, Chronic - metabolism ; Kidney Failure, Chronic - therapy ; Kidney Failure, Chronic - urine ; Kinetics ; Male ; Phosphates - metabolism ; Phosphates - urine ; Renal Dialysis ; Urea - urine
ispartofPediatric nephrology (Berlin, West), 1997-04, Vol.11 (2), p.193-195
lds50peer_reviewed
links
openurl$$Topenurl_article
thumbnail$$Usyndetics_thumb_exl
backlink$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9090662$$D View this record in MEDLINE/PubMed
search
creatorcontrib
0Fischbach, M
1Boudailliez, B
2Foulard, M
title
0Phosphate end dialysis value: a misleading parameter of hemodialysis efficiency. French Society for Pediatric Nephrology
1Pediatric nephrology (Berlin, West)
addtitlePediatr Nephrol
descriptionDespite low end dialysis serum phosphate levels (Pe) the control of phosphate retention remains often unsatisfactory in dialyzed patients. In order to assess the value of Pe in dialyzed children as an indicator of dialytic phosphate removal, we studied serum phosphate kinetics over the period of dialysis and post dialysis and compared these with urea kinetics. A multicenter study was conducted in the 21 French pediatric hemodialysis units and included 144 children under 15 years of age. Blood urea and phosphate concentrations were measured at the beginning, at 45 min later, at the end of dialysis, and 30 min post dialysis. At 60 min and at 360 min post dialysis measurements were made only for a subgroup of 12 children. From the serum levels, reduction ratios for urea (URR) and phosphate (PRR) and post dialysis rebound for urea (PDUR) and phosphate (PDPR) were calculated. URR (over the dialysis session, 72% +/- 9%) was higher than PRR (47% +/- 12%). Moreover, urea removal continued throughout the dialysis period, while most of the reduction in phosphate occurred in the initial dialysis period. Post dialysis urea rebound was limited to the 60th min post dialysis, whereas post dialysis phosphate rebound occurred until the 360th min post dialysis; by this time the serum phosphate levels had almost reached the predialysis levels. In summary, serum phosphate kinetics over dialysis and post dialysis periods in children appear to be misleading for the quantification of phosphate removal, i.e., phosphate clearance is a poor indicator of dialytic phosphate removal.
subject
0Adolescent
1Child
2Child, Preschool
3Female
4France
5Humans
6Infant
7Kidney Failure, Chronic - metabolism
8Kidney Failure, Chronic - therapy
9Kidney Failure, Chronic - urine
10Kinetics
11Male
12Phosphates - metabolism
13Phosphates - urine
14Renal Dialysis
15Urea - urine
issn
00931-041X
11432-198X
fulltextfalse
rsrctypearticle
creationdate1997
recordtypearticle
recordideNo9kF1LwzAYhYMoc05_gpAr7ypJPxPvZDgVhg7cxe5KPt6skbapSSv23xtweHXg8HDgOWdoSfMsTShnh3O0JDyjCcnp4RJdhfBJCGEFKxdowQknZZku0c-ucWFoxAgYeo21Fe0cbMDfop3gAQvc2dCC0LY_4kF40cEIHjuDG-jcPw3GWGWhV_M93viYDf5wsRhnbJzHO4jk6K3CbzA03rXuOF-jCyPaADenXKH95mm_fkm278-v68dtMhTRg1PCJEitWJ4VUmQMSpkrKioaS8GqVKeZMSVVKcujJ9OFyJTkisuKl0obskJ3f7ODd18ThLGOQgraVvTgplBXjPF4Eovg7QmcZAe6HrzthJ_r01PkF1GSaLc
startdate199704
enddate199704
creator
0Fischbach, M
1Boudailliez, B
2Foulard, M
scope
0CGR
1CUY
2CVF
3ECM
4EIF
5NPM
67X8
sort
creationdate199704
titlePhosphate end dialysis value: a misleading parameter of hemodialysis efficiency. French Society for Pediatric Nephrology
authorFischbach, M ; Boudailliez, B ; Foulard, M
facets
frbrtype5
frbrgroupidcdi_FETCH-LOGICAL-p532-9108bebdc8435ba38e6b4c1a71ebda872d23ff61c2840418d5a3cb9c9b796cdf0
rsrctypearticles
prefilterarticles
languageeng
creationdate1997
topic
0Adolescent
1Child
2Child, Preschool
3Female
4France
5Humans
6Infant
7Kidney Failure, Chronic - metabolism
8Kidney Failure, Chronic - therapy
9Kidney Failure, Chronic - urine
10Kinetics
11Male
12Phosphates - metabolism
13Phosphates - urine
14Renal Dialysis
15Urea - urine
toplevelpeer_reviewed
creatorcontrib
0Fischbach, M
1Boudailliez, B
2Foulard, M
collection
0Medline
1MEDLINE
2MEDLINE (Ovid)
3MEDLINE
4MEDLINE
5PubMed
6MEDLINE - Academic
jtitlePediatric nephrology (Berlin, West)
delivery
delcategoryRemote Search Resource
fulltextno_fulltext
addata
au
0Fischbach, M
1Boudailliez, B
2Foulard, M
formatjournal
genrearticle
ristypeJOUR
atitlePhosphate end dialysis value: a misleading parameter of hemodialysis efficiency. French Society for Pediatric Nephrology
jtitlePediatric nephrology (Berlin, West)
addtitlePediatr Nephrol
date1997-04
risdate1997
volume11
issue2
spage193
epage195
pages193-195
issn0931-041X
eissn1432-198X
abstractDespite low end dialysis serum phosphate levels (Pe) the control of phosphate retention remains often unsatisfactory in dialyzed patients. In order to assess the value of Pe in dialyzed children as an indicator of dialytic phosphate removal, we studied serum phosphate kinetics over the period of dialysis and post dialysis and compared these with urea kinetics. A multicenter study was conducted in the 21 French pediatric hemodialysis units and included 144 children under 15 years of age. Blood urea and phosphate concentrations were measured at the beginning, at 45 min later, at the end of dialysis, and 30 min post dialysis. At 60 min and at 360 min post dialysis measurements were made only for a subgroup of 12 children. From the serum levels, reduction ratios for urea (URR) and phosphate (PRR) and post dialysis rebound for urea (PDUR) and phosphate (PDPR) were calculated. URR (over the dialysis session, 72% +/- 9%) was higher than PRR (47% +/- 12%). Moreover, urea removal continued throughout the dialysis period, while most of the reduction in phosphate occurred in the initial dialysis period. Post dialysis urea rebound was limited to the 60th min post dialysis, whereas post dialysis phosphate rebound occurred until the 360th min post dialysis; by this time the serum phosphate levels had almost reached the predialysis levels. In summary, serum phosphate kinetics over dialysis and post dialysis periods in children appear to be misleading for the quantification of phosphate removal, i.e., phosphate clearance is a poor indicator of dialytic phosphate removal.
copGermany
pmid9090662