schliessen

Filtern

 

Bibliotheken

Systolic Right Ventricular Function in Preterm and Term Neonates: Reference Values of the Tricuspid Annular Plane Systolic Excursion (TAPSE) in 258 Patients and Calculation of Z-Score Values

Background: The tricuspid annular plane systolic excursion (TAPSE) is an echocardiographic measurement to assess right ventricular systolic function in adults and children. Objective: We determined growth- and birth weight-related changes of TAPSE to establish reference values in preterm and term ne... Full description

Journal Title: Neonatology (Basel Switzerland), 2011-06, Vol.100 (1), p.85-92
Main Author: Koestenberger, Martin
Other Authors: Nagel, Bert , Ravekes, William , Urlesberger, Berndt , Raith, Wolfgang , Avian, Alexander , Halb, Verena , Cvirn, Gerhard , Fritsch, Peter , Gamillscheg, Andreas
Format: Electronic Article Electronic Article
Language: English
Subjects:
Quelle: Alma/SFX Local Collection
Publisher: Basel, Switzerland: S. Karger AG
ID: ISSN: 1661-7800
Link: https://www.ncbi.nlm.nih.gov/pubmed/21273793
Zum Text:
SendSend as email Add to Book BagAdd to Book Bag
Staff View
recordid: cdi_pubmed_primary_21273793
title: Systolic Right Ventricular Function in Preterm and Term Neonates: Reference Values of the Tricuspid Annular Plane Systolic Excursion (TAPSE) in 258 Patients and Calculation of Z-Score Values
format: Article
creator:
  • Koestenberger, Martin
  • Nagel, Bert
  • Ravekes, William
  • Urlesberger, Berndt
  • Raith, Wolfgang
  • Avian, Alexander
  • Halb, Verena
  • Cvirn, Gerhard
  • Fritsch, Peter
  • Gamillscheg, Andreas
subjects:
  • Adult
  • Echocardiography - methods
  • Female
  • Gestational Age
  • Humans
  • Infant, Newborn
  • Infant, Premature - physiology
  • Infant, Premature, Diseases - diagnostic imaging
  • Infant, Premature, Diseases - physiopathology
  • Male
  • Original Paper
  • Pregnancy
  • Reference Values
  • Research Design
  • Systole - physiology
  • Term Birth - physiology
  • Tricuspid Valve - anatomy & histology
  • Tricuspid Valve - diagnostic imaging
  • Tricuspid Valve - physiopathology
  • Ventricular Dysfunction, Right - diagnostic imaging
  • Ventricular Dysfunction, Right - physiopathology
  • Ventricular Function, Right - physiology
ispartof: Neonatology (Basel, Switzerland), 2011-06, Vol.100 (1), p.85-92
description: Background: The tricuspid annular plane systolic excursion (TAPSE) is an echocardiographic measurement to assess right ventricular systolic function in adults and children. Objective: We determined growth- and birth weight-related changes of TAPSE to establish reference values in preterm and term neonates. Methods: A prospective study was conducted in a group of 258 preterm and term neonates (age: 25+0 to 40+6 weeks of gestation, birth weight: 530–4,200 g). Results: The TAPSE ranged from a mean of 0.44 cm (Z-score ±2: 0.30–0.59 cm) in preterm neonates in the 26th week of gestation to 1.03 cm (Z-score ±2: 0.85–1.21 cm) in term neonates in the 41st week of gestation. The TAPSE values increased in a linear way from the 26th to 41st week of gestation. TAPSE, week of gestation and weight are strongly correlated: Pearson’s correlation coefficient was 0.93 for week of gestation – TAPSE (p < 0.001), 0.93 for week of gestation – birth weight (p < 0.001), and 0.89 for birth weight – TAPSE (p < 0.001). There was no statistically significant difference of normal TAPSE values between female and male patients (p = 0.987). Conclusion: Z-scores of TAPSE values were calculated and percentile charts were established to serve as reference data for ready application in preterm and term neonates with structurally normal hearts and with congenital heart disease in the future.
language: eng
source: Alma/SFX Local Collection
identifier: ISSN: 1661-7800
fulltext: fulltext
issn:
  • 1661-7800
  • 1661-7819
url: Link


@attributes
NO1
SEARCH_ENGINEprimo_central_multiple_fe
SEARCH_ENGINE_TYPEPrimo Central Search Engine
RANK2.5258963
LOCALfalse
PrimoNMBib
record
control
sourceidproquest_pubme
recordidTN_cdi_pubmed_primary_21273793
sourceformatXML
sourcesystemPC
sourcerecordid873705814
originalsourceidFETCH-LOGICAL-1389t-9746137bffce2502e65afc8816e73683c6ed1497d13235450f805b47081fc21c3
addsrcrecordideNptkc1u1DAURiMEoj-w4AWQxQLoItTXHjsOu9FoCkhVO-oMXbCJPM5N65JxBtuR2pfj2XBm2iwqVr6L4_N99s2yd0C_AIjylFLKGaNUvsgOQUrICwXly3Gm9CA7CuGOUiGEZK-zAwas4EXJD7O_y4cQu9YacmVvbiO5Rhe9NX2rPTnrnYm2c8Q6svAY0W-IdjVZDcMFdk5HDF_JFTbo0Rkk17rtMZCuIfEWyWrwhK2tydS5nXDRaodkTJzfm96HIeDzarpYzk-GICYUWehoU4-wS5vpdqizK5LMv_Kl6fxT1pvsVaPbgG8fz-Ps59l8Nfuen19--zGbnufAVRnzsphI4MW6aQwyQRlKoRujFEgsuFTcSKxhUhY1cMbFRNBGUbGeFFRBYxgYfpx92nu3vvuTcmO1scFgOzyo60Ol0ndSoWCSyA_PyLuu9y6VS5BkSpVsgE72kPFdCB6bauvtRvuHCmg1rLQaV5rY94_Cfr3BeiSfdpiA02cyY-Puv6LXtv2v8uP-xm_tb9CPyov5JaMAkEgKVAn-D-Z5tZ8
sourcetypeAggregation Database
isCDItrue
recordtypearticle
pqid876288924
display
typearticle
titleSystolic Right Ventricular Function in Preterm and Term Neonates: Reference Values of the Tricuspid Annular Plane Systolic Excursion (TAPSE) in 258 Patients and Calculation of Z-Score Values
sourceAlma/SFX Local Collection
creatorKoestenberger, Martin ; Nagel, Bert ; Ravekes, William ; Urlesberger, Berndt ; Raith, Wolfgang ; Avian, Alexander ; Halb, Verena ; Cvirn, Gerhard ; Fritsch, Peter ; Gamillscheg, Andreas
creatorcontribKoestenberger, Martin ; Nagel, Bert ; Ravekes, William ; Urlesberger, Berndt ; Raith, Wolfgang ; Avian, Alexander ; Halb, Verena ; Cvirn, Gerhard ; Fritsch, Peter ; Gamillscheg, Andreas
descriptionBackground: The tricuspid annular plane systolic excursion (TAPSE) is an echocardiographic measurement to assess right ventricular systolic function in adults and children. Objective: We determined growth- and birth weight-related changes of TAPSE to establish reference values in preterm and term neonates. Methods: A prospective study was conducted in a group of 258 preterm and term neonates (age: 25+0 to 40+6 weeks of gestation, birth weight: 530–4,200 g). Results: The TAPSE ranged from a mean of 0.44 cm (Z-score ±2: 0.30–0.59 cm) in preterm neonates in the 26th week of gestation to 1.03 cm (Z-score ±2: 0.85–1.21 cm) in term neonates in the 41st week of gestation. The TAPSE values increased in a linear way from the 26th to 41st week of gestation. TAPSE, week of gestation and weight are strongly correlated: Pearson’s correlation coefficient was 0.93 for week of gestation – TAPSE (p < 0.001), 0.93 for week of gestation – birth weight (p < 0.001), and 0.89 for birth weight – TAPSE (p < 0.001). There was no statistically significant difference of normal TAPSE values between female and male patients (p = 0.987). Conclusion: Z-scores of TAPSE values were calculated and percentile charts were established to serve as reference data for ready application in preterm and term neonates with structurally normal hearts and with congenital heart disease in the future.
identifier
0ISSN: 1661-7800
1EISSN: 1661-7819
2DOI: 10.1159/000322006
3PMID: 21273793
languageeng
publisherBasel, Switzerland: S. Karger AG
subjectAdult ; Echocardiography - methods ; Female ; Gestational Age ; Humans ; Infant, Newborn ; Infant, Premature - physiology ; Infant, Premature, Diseases - diagnostic imaging ; Infant, Premature, Diseases - physiopathology ; Male ; Original Paper ; Pregnancy ; Reference Values ; Research Design ; Systole - physiology ; Term Birth - physiology ; Tricuspid Valve - anatomy & histology ; Tricuspid Valve - diagnostic imaging ; Tricuspid Valve - physiopathology ; Ventricular Dysfunction, Right - diagnostic imaging ; Ventricular Dysfunction, Right - physiopathology ; Ventricular Function, Right - physiology
ispartofNeonatology (Basel, Switzerland), 2011-06, Vol.100 (1), p.85-92
rights
02011 S. Karger AG, Basel
1Copyright © 2011 S. Karger AG, Basel.
lds50peer_reviewed
citedbyFETCH-LOGICAL-1389t-9746137bffce2502e65afc8816e73683c6ed1497d13235450f805b47081fc21c3
citesFETCH-LOGICAL-1389t-9746137bffce2502e65afc8816e73683c6ed1497d13235450f805b47081fc21c3
links
openurl$$Topenurl_article
openurlfulltext$$Topenurlfull_article
thumbnail$$Usyndetics_thumb_exl
backlink$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21273793$$D View this record in MEDLINE/PubMed
search
creatorcontrib
0Koestenberger, Martin
1Nagel, Bert
2Ravekes, William
3Urlesberger, Berndt
4Raith, Wolfgang
5Avian, Alexander
6Halb, Verena
7Cvirn, Gerhard
8Fritsch, Peter
9Gamillscheg, Andreas
title
0Systolic Right Ventricular Function in Preterm and Term Neonates: Reference Values of the Tricuspid Annular Plane Systolic Excursion (TAPSE) in 258 Patients and Calculation of Z-Score Values
1Neonatology (Basel, Switzerland)
addtitleNeonatology
descriptionBackground: The tricuspid annular plane systolic excursion (TAPSE) is an echocardiographic measurement to assess right ventricular systolic function in adults and children. Objective: We determined growth- and birth weight-related changes of TAPSE to establish reference values in preterm and term neonates. Methods: A prospective study was conducted in a group of 258 preterm and term neonates (age: 25+0 to 40+6 weeks of gestation, birth weight: 530–4,200 g). Results: The TAPSE ranged from a mean of 0.44 cm (Z-score ±2: 0.30–0.59 cm) in preterm neonates in the 26th week of gestation to 1.03 cm (Z-score ±2: 0.85–1.21 cm) in term neonates in the 41st week of gestation. The TAPSE values increased in a linear way from the 26th to 41st week of gestation. TAPSE, week of gestation and weight are strongly correlated: Pearson’s correlation coefficient was 0.93 for week of gestation – TAPSE (p < 0.001), 0.93 for week of gestation – birth weight (p < 0.001), and 0.89 for birth weight – TAPSE (p < 0.001). There was no statistically significant difference of normal TAPSE values between female and male patients (p = 0.987). Conclusion: Z-scores of TAPSE values were calculated and percentile charts were established to serve as reference data for ready application in preterm and term neonates with structurally normal hearts and with congenital heart disease in the future.
subject
0Adult
1Echocardiography - methods
2Female
3Gestational Age
4Humans
5Infant, Newborn
6Infant, Premature - physiology
7Infant, Premature, Diseases - diagnostic imaging
8Infant, Premature, Diseases - physiopathology
9Male
10Original Paper
11Pregnancy
12Reference Values
13Research Design
14Systole - physiology
15Term Birth - physiology
16Tricuspid Valve - anatomy & histology
17Tricuspid Valve - diagnostic imaging
18Tricuspid Valve - physiopathology
19Ventricular Dysfunction, Right - diagnostic imaging
20Ventricular Dysfunction, Right - physiopathology
21Ventricular Function, Right - physiology
issn
01661-7800
11661-7819
fulltexttrue
rsrctypearticle
creationdate2011
recordtypearticle
recordideNptkc1u1DAURiMEoj-w4AWQxQLoItTXHjsOu9FoCkhVO-oMXbCJPM5N65JxBtuR2pfj2XBm2iwqVr6L4_N99s2yd0C_AIjylFLKGaNUvsgOQUrICwXly3Gm9CA7CuGOUiGEZK-zAwas4EXJD7O_y4cQu9YacmVvbiO5Rhe9NX2rPTnrnYm2c8Q6svAY0W-IdjVZDcMFdk5HDF_JFTbo0Rkk17rtMZCuIfEWyWrwhK2tydS5nXDRaodkTJzfm96HIeDzarpYzk-GICYUWehoU4-wS5vpdqizK5LMv_Kl6fxT1pvsVaPbgG8fz-Ps59l8Nfuen19--zGbnufAVRnzsphI4MW6aQwyQRlKoRujFEgsuFTcSKxhUhY1cMbFRNBGUbGeFFRBYxgYfpx92nu3vvuTcmO1scFgOzyo60Ol0ndSoWCSyA_PyLuu9y6VS5BkSpVsgE72kPFdCB6bauvtRvuHCmg1rLQaV5rY94_Cfr3BeiSfdpiA02cyY-Puv6LXtv2v8uP-xm_tb9CPyov5JaMAkEgKVAn-D-Z5tZ8
startdate201106
enddate201106
creator
0Koestenberger, Martin
1Nagel, Bert
2Ravekes, William
3Urlesberger, Berndt
4Raith, Wolfgang
5Avian, Alexander
6Halb, Verena
7Cvirn, Gerhard
8Fritsch, Peter
9Gamillscheg, Andreas
generalS. Karger AG
scope
0CGR
1CUY
2CVF
3ECM
4EIF
5NPM
6AAYXX
7CITATION
83V.
97X7
107XB
1188A
1288E
1388I
148AO
158FE
168FH
178FI
188FJ
198FK
208FW
218G5
22ABUWG
23AZQEC
24BBNVY
25BENPR
26BHPHI
27DWQXO
28FYUFA
29GHDGH
30GNUQQ
31GUQSH
32HCIFZ
33K9.
34LK8
35M0L
36M0S
37M1P
38M2O
39M2P
40M7P
41MBDVC
42PADUT
43PQEST
44PQQKQ
45PQUKI
46PRINS
47Q9U
487X8
sort
creationdate201106
titleSystolic Right Ventricular Function in Preterm and Term Neonates: Reference Values of the Tricuspid Annular Plane Systolic Excursion (TAPSE) in 258 Patients and Calculation of Z-Score Values
authorKoestenberger, Martin ; Nagel, Bert ; Ravekes, William ; Urlesberger, Berndt ; Raith, Wolfgang ; Avian, Alexander ; Halb, Verena ; Cvirn, Gerhard ; Fritsch, Peter ; Gamillscheg, Andreas
facets
frbrtype5
frbrgroupidcdi_FETCH-LOGICAL-1389t-9746137bffce2502e65afc8816e73683c6ed1497d13235450f805b47081fc21c3
rsrctypearticles
prefilterarticles
languageeng
creationdate2011
topic
0Adult
1Echocardiography - methods
2Female
3Gestational Age
4Humans
5Infant, Newborn
6Infant, Premature - physiology
7Infant, Premature, Diseases - diagnostic imaging
8Infant, Premature, Diseases - physiopathology
9Male
10Original Paper
11Pregnancy
12Reference Values
13Research Design
14Systole - physiology
15Term Birth - physiology
16Tricuspid Valve - anatomy & histology
17Tricuspid Valve - diagnostic imaging
18Tricuspid Valve - physiopathology
19Ventricular Dysfunction, Right - diagnostic imaging
20Ventricular Dysfunction, Right - physiopathology
21Ventricular Function, Right - physiology
toplevel
0peer_reviewed
1online_resources
creatorcontrib
0Koestenberger, Martin
1Nagel, Bert
2Ravekes, William
3Urlesberger, Berndt
4Raith, Wolfgang
5Avian, Alexander
6Halb, Verena
7Cvirn, Gerhard
8Fritsch, Peter
9Gamillscheg, Andreas
collection
0Medline
1MEDLINE
2MEDLINE (Ovid)
3MEDLINE
4MEDLINE
5PubMed
6CrossRef
7ProQuest Central (Corporate)
8Health & Medical Collection
9ProQuest Central (purchase pre-March 2016)
10Biology Database (Alumni Edition)
11Medical Database (Alumni Edition)
12Science Database (Alumni Edition)
13ProQuest Pharma Collection
14ProQuest SciTech Collection
15ProQuest Natural Science Collection
16Hospital Premium Collection
17Hospital Premium Collection (Alumni Edition)
18ProQuest Central (Alumni) (purchase pre-March 2016)
19Curriculum Essentials
20Research Library (Alumni Edition)
21ProQuest Central (Alumni Edition)
22ProQuest Central Essentials
23Biological Science Collection
24ProQuest Central
25Natural Science Collection
26ProQuest Central Korea
27Health Research Premium Collection
28Health Research Premium Collection (Alumni)
29ProQuest Central Student
30Research Library Prep
31SciTech Premium Collection
32ProQuest Health & Medical Complete (Alumni)
33ProQuest Biological Science Collection
34Biology Database
35Health & Medical Collection (Alumni Edition)
36Medical Database
37Research Library
38Science Database
39Biological Science Database
40Research Library (Corporate)
41Research Library China
42ProQuest One Academic Eastern Edition
43ProQuest One Academic
44ProQuest One Academic UKI Edition
45ProQuest Central China
46ProQuest Central Basic
47MEDLINE - Academic
jtitleNeonatology (Basel, Switzerland)
delivery
delcategoryRemote Search Resource
fulltextfulltext
addata
au
0Koestenberger, Martin
1Nagel, Bert
2Ravekes, William
3Urlesberger, Berndt
4Raith, Wolfgang
5Avian, Alexander
6Halb, Verena
7Cvirn, Gerhard
8Fritsch, Peter
9Gamillscheg, Andreas
formatjournal
genrearticle
ristypeJOUR
atitleSystolic Right Ventricular Function in Preterm and Term Neonates: Reference Values of the Tricuspid Annular Plane Systolic Excursion (TAPSE) in 258 Patients and Calculation of Z-Score Values
jtitleNeonatology (Basel, Switzerland)
addtitleNeonatology
date2011-06
risdate2011
volume100
issue1
spage85
epage92
pages85-92
issn1661-7800
eissn1661-7819
abstractBackground: The tricuspid annular plane systolic excursion (TAPSE) is an echocardiographic measurement to assess right ventricular systolic function in adults and children. Objective: We determined growth- and birth weight-related changes of TAPSE to establish reference values in preterm and term neonates. Methods: A prospective study was conducted in a group of 258 preterm and term neonates (age: 25+0 to 40+6 weeks of gestation, birth weight: 530–4,200 g). Results: The TAPSE ranged from a mean of 0.44 cm (Z-score ±2: 0.30–0.59 cm) in preterm neonates in the 26th week of gestation to 1.03 cm (Z-score ±2: 0.85–1.21 cm) in term neonates in the 41st week of gestation. The TAPSE values increased in a linear way from the 26th to 41st week of gestation. TAPSE, week of gestation and weight are strongly correlated: Pearson’s correlation coefficient was 0.93 for week of gestation – TAPSE (p < 0.001), 0.93 for week of gestation – birth weight (p < 0.001), and 0.89 for birth weight – TAPSE (p < 0.001). There was no statistically significant difference of normal TAPSE values between female and male patients (p = 0.987). Conclusion: Z-scores of TAPSE values were calculated and percentile charts were established to serve as reference data for ready application in preterm and term neonates with structurally normal hearts and with congenital heart disease in the future.
copBasel, Switzerland
pubS. Karger AG
pmid21273793
doi10.1159/000322006
tpages8