Improvement of Efficiency and Flexibility in Multi-slice Helical CT - Improvement of Efficiency and Flexibility in Multi-slice Helical CT

One of the main aspects in computed tomography (CT) development is to make CT rapidly scan a large longitudinal volume with high z-axis resolution. The combination of helical scanning with multi-slice CT is a promising approach. Image reconstruction in multi-slice CT becomes, therefore, the major ch... Full description

Journal Title: 上海交通大学学报:英文版 - Journal of Shanghai Jiaotong university 2008, Vol.13(4), pp.408-412
Main Author: 孙文武
Other Authors: 陈思平 , 庄天戈 , SUN Wen-wu , CHEN Si-ping , ZHUANG Tian-ge
Format: Electronic Article Electronic Article
Language:
Subjects:
ID: ISSN: 1007-1172
Zum Text:
SendSend as email Add to Book BagAdd to Book Bag
Staff View
recordid: cqvip27979389
title: Improvement of Efficiency and Flexibility in Multi-slice Helical CT - Improvement of Efficiency and Flexibility in Multi-slice Helical CT
format: Article
creator:
  • 孙文武
  • 陈思平
  • 庄天戈
  • SUN Wen-wu , CHEN Si-ping , ZHUANG Tian-ge
subjects:
  • X线摄影
  • 医疗器械
  • 螺旋内插法
  • 柔曲性
  • Multi-Slice Computed Tomography
  • Helical Interpolation
  • Rebinning
  • Filter Interpolation
ispartof: 上海交通大学学报:英文版 - Journal of Shanghai Jiaotong university, 2008, Vol.13(4), pp.408-412
description: One of the main aspects in computed tomography (CT) development is to make CT rapidly scan a large longitudinal volume with high z-axis resolution. The combination of helical scanning with multi-slice CT is a promising approach. Image reconstruction in multi-slice CT becomes, therefore, the major challenge. Known algorithms need to derive the complementary data or work only for certain range of pitches. A reconstruction algorithm was presented that works with the direct data as well as arbitrary pitches. Filter interpolation based on the proposed method was implemented easy. The results of computer simulations under kinds of conditions for four-slice CT were presented. The proposed method can obtain higher efficiency than the conventional method.
language:
source:
identifier: ISSN: 1007-1172
fulltext: fulltext
issn:
  • 1007-1172
  • 10071172
url: Link


@attributes
ID769511419
RANK0.07
NO1
SEARCH_ENGINEprimo_central_multiple_fe
SEARCH_ENGINE_TYPEPrimo Central Search Engine
LOCALfalse
PrimoNMBib
record
control
sourcerecordid27979389
sourceidcqvip
recordidTN_cqvip27979389
sourceformatDC
sourcesystemPC
pqid34901969
display
typearticle
titleImprovement of Efficiency and Flexibility in Multi-slice Helical CT - Improvement of Efficiency and Flexibility in Multi-slice Helical CT
creator孙文武 ; 陈思平 ; 庄天戈 ; SUN Wen-wu , CHEN Si-ping , ZHUANG Tian-ge
ispartof上海交通大学学报:英文版 - Journal of Shanghai Jiaotong university, 2008, Vol.13(4), pp.408-412
identifierISSN: 1007-1172
subjectX线摄影 ; 医疗器械 ; 螺旋内插法 ; 柔曲性 ; Multi-Slice Computed Tomography; Helical Interpolation; Rebinning; Filter Interpolation
descriptionOne of the main aspects in computed tomography (CT) development is to make CT rapidly scan a large longitudinal volume with high z-axis resolution. The combination of helical scanning with multi-slice CT is a promising approach. Image reconstruction in multi-slice CT becomes, therefore, the major challenge. Known algorithms need to derive the complementary data or work only for certain range of pitches. A reconstruction algorithm was presented that works with the direct data as well as arbitrary pitches. Filter interpolation based on the proposed method was implemented easy. The results of computer simulations under kinds of conditions for four-slice CT were presented. The proposed method can obtain higher efficiency than the conventional method.
relation作者单位: Nanchang Institute of Aeronautical Technology, Nanchang 330063, China Shenzhen University, Shenzhen 518057, China Department of Biomedical Engineering, Shanghai Jiaotong University, Shanghai 200240, China
source
version4
lds50peer_reviewed
links
openurl$$Topenurl_article
openurlfulltext$$Topenurlfull_article
thumbnail$$Uhttp://image.cqvip.com/vip1000/qk/85391X/85391X.jpg
search
creatorcontrib
0孙文武
1陈思平
2庄天戈
3SUN Wen-wu , CHEN Si-ping , ZHUANG Tian-ge
4Nanchang Institute of Aeronautical Technology, Nanchang 330063, China Shenzhen University, Shenzhen 518057, China Department of Biomedical Engineering, Shanghai Jiaotong University, Shanghai 200240, China
titleImprovement of Efficiency and Flexibility in Multi-slice Helical CT
descriptionOne of the main aspects in computed tomography (CT) development is to make CT rapidly scan a large longitudinal volume with high z-axis resolution. The combination of helical scanning with multi-slice CT is a promising approach. Image reconstruction in multi-slice CT becomes, therefore, the major challenge. Known algorithms need to derive the complementary data or work only for certain range of pitches. A reconstruction algorithm was presented that works with the direct data as well as arbitrary pitches. Filter interpolation based on the proposed method was implemented easy. The results of computer simulations under kinds of conditions for four-slice CT were presented. The proposed method can obtain higher efficiency than the conventional method.
subject
0X线摄影
1医疗器械
2螺旋内插法
3柔曲性
4Multi-Slice Computed Tomography
5Helical Interpolation
6Rebinning
7Filter Interpolation
general
0chinese
1维普数据 (Chongqing VIP Information Co.)
sourceidcqvip
recordidcqvip27979389
issn
01007-1172
110071172
rsrctypearticle
creationdate2008
startdate20080101
enddate20081231
addtitle
0上海交通大学学报:英文版
1Journal of Shanghai Jiaotong university
searchscopecqvip
scopecqvip
lsr01
0Nanchang Institute of Aeronautical Technology, Nanchang 330063, China Shenzhen University, Shenzhen 518057, China Department of Biomedical Engineering, Shanghai Jiaotong University, Shanghai 200240, China
1SUN Wen-wu , CHEN Si-ping , ZHUANG Tian-ge (1. Nanchang Institute of Aeronautical Technology, Nanchang 330063, China; 2. Shenzhen University, Shenzhen 518057, China; 3. Department of Biomedical Engineering, Shanghai Jiaotong University, Shanghai 200240, China)
citationpf 408 pt 412 vol 13 issue 4
lsr30VSR-Enriched:[eissn, pages, pqid, doi, date]
sort
titleImprovement of Efficiency and Flexibility in Multi-slice Helical CT - Improvement of Efficiency and Flexibility in Multi-slice Helical CT
author孙文武 ; 陈思平 ; 庄天戈 ; SUN Wen-wu , CHEN Si-ping , ZHUANG Tian-ge
creationdate20080000
lso0120080000
facets
frbrgroupid9206337164687536135
frbrtype5
creationdate2008
topic
0X线摄影
1医疗器械
2螺旋内插法
3柔曲性
4Multi-Slice Computed Tomography; Helical Interpolation; Rebinning; Filter Interpolation
collection维普资讯 (Chongqing VIP Information Co.)
prefilterarticles
rsrctypearticles
creatorcontrib
0孙文武
1陈思平
2庄天戈
3SUN Wen-wu , CHEN Si-ping , ZHUANG Tian-ge
jtitle
0上海交通大学学报:英文版
1Journal of Shanghai Jiaotong university
toplevelpeer_reviewed
delivery
delcategoryRemote Search Resource
fulltextfulltext
addata
au
0孙文武
1陈思平
2庄天戈
3SUN Wen-wu , CHEN Si-ping , ZHUANG Tian-ge
atitleImprovement of Efficiency and Flexibility in Multi-slice Helical CT - Improvement of Efficiency and Flexibility in Multi-slice Helical CT
jtitle上海交通大学学报:英文版
risdate2008
volume13
issue4
part85391X
spage408
epage412
issn1007-1172
coden85391X
formatjournal
genrearticle
ristypeJOUR
abstractOne of the main aspects in computed tomography (CT) development is to make CT rapidly scan a large longitudinal volume with high z-axis resolution. The combination of helical scanning with multi-slice CT is a promising approach. Image reconstruction in multi-slice CT becomes, therefore, the major challenge. Known algorithms need to derive the complementary data or work only for certain range of pitches. A reconstruction algorithm was presented that works with the direct data as well as arbitrary pitches. Filter interpolation based on the proposed method was implemented easy. The results of computer simulations under kinds of conditions for four-slice CT were presented. The proposed method can obtain higher efficiency than the conventional method.
lad0185391X
pages408-412
doi10.1007/s12204-008-0408-x
eissn19958188
date2008-08