schliessen

Filtern

 

Bibliotheken

THE IMPROVEMENT AND APPLICATION OF EI-GUN (ELECTRICAL INSEMINATION GUN) FOR ARTIFICIAL INSEMINATION (AI) USING GOAT FRESH SEMEN

Electrical Insemination Gun (EI-GUN) was a tool for Artificial Insemination (AI) using fresh semen with an electric control system. The research objective was to produced EI-GUN for AI using fresh semen on small ruminants (goat). The research was conducted from March to June 2015. The process of EI-... Full description

Journal Title: Jurnal Ternak Tropika 01 March 2017, Vol.17(2), pp.16-22
Main Author: Mirsa Ita Dewi
Other Authors: Gatot Ciptadi , Lilik Eka Radiati
Format: Electronic Article Electronic Article
Language: ind
Quelle: Directory of Open Access Journals (DOAJ)
ID: ISSN: 1411-6146 ; E-ISSN: 2503-1007 ; DOI: 10.21776/ub.jtapro.2016.017.02.3
Zum Text:
SendSend as email Add to Book BagAdd to Book Bag
Staff View
recordid: doaj_soai_doaj_org_article_6396bfd8b92c4bc5b4e20a4ae9691faf
title: THE IMPROVEMENT AND APPLICATION OF EI-GUN (ELECTRICAL INSEMINATION GUN) FOR ARTIFICIAL INSEMINATION (AI) USING GOAT FRESH SEMEN
format: Article
creator:
  • Mirsa Ita Dewi
  • Gatot Ciptadi
  • Lilik Eka Radiati
ispartof: Jurnal Ternak Tropika, 01 March 2017, Vol.17(2), pp.16-22
description: Electrical Insemination Gun (EI-GUN) was a tool for Artificial Insemination (AI) using fresh semen with an electric control system. The research objective was to produced EI-GUN for AI using fresh semen on small ruminants (goat). The research was conducted from March to June 2015. The process of EI-GUN creation implemented in Design and Prototype Laboratory and Aero Modeling Research Laboratory at Engineering Faculty, University of Brawijaya (UB). Testing tools EI-GUN on goat was conducted in the Sumber Sekar Laboratory, Animal Husbandry Faculty, UB.  The methods of research were literature study, tool specification determination, designing EI-GUN, running test, semen evaluation passed EI-GUN and application on Goat. EI-GUN has seven important parts, which supports each other in this operating system. Those parts consist of stylet, servo, system controlled, insemination pump, connecting rod, battery, and holder. EI-GUN work system sucked the semen into insemination pump as much as 5 ml, and release the semen 0.25 ml appropriate standard of AI. It was applicable for 20 times AI. The results showed that the cell motility of spermatozoa ≥ 70% were still in ranging of Indonesian National Standard (SNI).   Keywords: artificial insemination, EI-GUN, fresh semen.
language: ind
source: Directory of Open Access Journals (DOAJ)
identifier: ISSN: 1411-6146 ; E-ISSN: 2503-1007 ; DOI: 10.21776/ub.jtapro.2016.017.02.3
fulltext: fulltext_linktorsrc
issn:
  • 1411-6146
  • 14116146
  • 2503-1007
  • 25031007
url: Link


@attributes
ID486738416
RANK0.07
NO1
SEARCH_ENGINEprimo_central_multiple_fe
SEARCH_ENGINE_TYPEPrimo Central Search Engine
LOCALfalse
PrimoNMBib
record
control
sourcerecordidoai_doaj_org_article_6396bfd8b92c4bc5b4e20a4ae9691faf
sourceiddoaj_s
recordidTN_doaj_soai_doaj_org_article_6396bfd8b92c4bc5b4e20a4ae9691faf
sourcesystemOther
dbidDOA
display
typearticle
titleTHE IMPROVEMENT AND APPLICATION OF EI-GUN (ELECTRICAL INSEMINATION GUN) FOR ARTIFICIAL INSEMINATION (AI) USING GOAT FRESH SEMEN
creatorMirsa Ita Dewi ; Gatot Ciptadi ; Lilik Eka Radiati
ispartofJurnal Ternak Tropika, 01 March 2017, Vol.17(2), pp.16-22
identifier
descriptionElectrical Insemination Gun (EI-GUN) was a tool for Artificial Insemination (AI) using fresh semen with an electric control system. The research objective was to produced EI-GUN for AI using fresh semen on small ruminants (goat). The research was conducted from March to June 2015. The process of EI-GUN creation implemented in Design and Prototype Laboratory and Aero Modeling Research Laboratory at Engineering Faculty, University of Brawijaya (UB). Testing tools EI-GUN on goat was conducted in the Sumber Sekar Laboratory, Animal Husbandry Faculty, UB.  The methods of research were literature study, tool specification determination, designing EI-GUN, running test, semen evaluation passed EI-GUN and application on Goat. EI-GUN has seven important parts, which supports each other in this operating system. Those parts consist of stylet, servo, system controlled, insemination pump, connecting rod, battery, and holder. EI-GUN work system sucked the semen into insemination pump as much as 5 ml, and release the semen 0.25 ml appropriate standard of AI. It was applicable for 20 times AI. The results showed that the cell motility of spermatozoa ≥ 70% were still in ranging of Indonesian National Standard (SNI).   Keywords: artificial insemination, EI-GUN, fresh semen.
languageind
oafree_for_read
sourceDirectory of Open Access Journals (DOAJ)
version2
lds50peer_reviewed
links
openurl$$Topenurl_article
openurlfulltext$$Topenurlfull_article
linktorsrc$$Uhttps://doaj.org/article/6396bfd8b92c4bc5b4e20a4ae9691faf$$EView_full_text_in_DOAJ
search
creatorcontrib
0Mirsa Ita Dewi
1Gatot Ciptadi
2Lilik Eka Radiati
titleTHE IMPROVEMENT AND APPLICATION OF EI-GUN (ELECTRICAL INSEMINATION GUN) FOR ARTIFICIAL INSEMINATION (AI) USING GOAT FRESH SEMEN
description

Electrical Insemination Gun (EI-GUN) was a tool for Artificial Insemination (AI) using fresh semen with an electric control system. The research objective was to produced EI-GUN for AI using fresh semen on small ruminants (goat). The research was conducted from March to June 2015. The process of EI-GUN creation implemented in Design and Prototype Laboratory and Aero Modeling Research Laboratory at Engineering Faculty, University of Brawijaya (UB). Testing tools EI-GUN on goat was conducted in the Sumber Sekar Laboratory, Animal Husbandry Faculty, UB.  The methods of research were literature study, tool specification determination, designing EI-GUN, running test, semen evaluation passed EI-GUN and application on Goat. EI-GUN has seven important parts, which supports each other in this operating system. Those parts consist of stylet, servo, system controlled, insemination pump, connecting rod, battery, and holder. EI-GUN work system sucked the semen into insemination pump as much as 5 ml, and release the semen 0.25 ml appropriate standard of AI. It was applicable for 20 times AI. The results showed that the cell motility of spermatozoa ≥ 70% were still in ranging of Indonesian National Standard (SNI).   Keywords: artificial insemination, EI-GUN, fresh semen.

general
0Indonesian
1University of Brawijaya
210.21776/ub.jtapro.2016.017.02.3
3Directory of Open Access Journals (DOAJ)
sourceiddoaj_s
recordiddoaj_soai_doaj_org_article_6396bfd8b92c4bc5b4e20a4ae9691faf
issn
01411-6146
114116146
22503-1007
325031007
rsrctypearticle
creationdate2017
addtitleJurnal Ternak Tropika
searchscopedoaj1
scopedoaj1
lsr45$$EView_full_text_in_DOAJ
tmp01Directory of Open Access Journals (DOAJ)
tmp02DOA
startdate20170301
enddate20170301
lsr40Jurnal Ternak Tropika, 01 March 2017, Vol.17 (2), pp.16-22
doi10.21776/ub.jtapro.2016.017.02.3
citationpf 16 pt 22 vol 17 issue 2
sort
titleTHE IMPROVEMENT AND APPLICATION OF EI-GUN (ELECTRICAL INSEMINATION GUN) FOR ARTIFICIAL INSEMINATION (AI) USING GOAT FRESH SEMEN
authorMirsa Ita Dewi ; Gatot Ciptadi ; Lilik Eka Radiati
creationdate20170301
lso0120170301
facets
frbrgroupid7427097535128101212
frbrtype5
newrecords20180425
languageind
collectionDirectory of Open Access Journals (DOAJ)
prefilterarticles
rsrctypearticles
creatorcontrib
0Mirsa Ita Dewi
1Gatot Ciptadi
2Lilik Eka Radiati
jtitleJurnal Ternak Tropika
creationdate2017
toplevelpeer_reviewed
delivery
delcategoryRemote Search Resource
fulltextfulltext_linktorsrc
addata
au
0Mirsa Ita Dewi
1Gatot Ciptadi
2Lilik Eka Radiati
atitleTHE IMPROVEMENT AND APPLICATION OF EI-GUN (ELECTRICAL INSEMINATION GUN) FOR ARTIFICIAL INSEMINATION (AI) USING GOAT FRESH SEMEN
jtitleJurnal Ternak Tropika
risdate20170301
volume17
issue2
spage16
epage22
pages16-22
issn1411-6146
eissn2503-1007
formatjournal
genrearticle
ristypeJOUR
abstract

Electrical Insemination Gun (EI-GUN) was a tool for Artificial Insemination (AI) using fresh semen with an electric control system. The research objective was to produced EI-GUN for AI using fresh semen on small ruminants (goat). The research was conducted from March to June 2015. The process of EI-GUN creation implemented in Design and Prototype Laboratory and Aero Modeling Research Laboratory at Engineering Faculty, University of Brawijaya (UB). Testing tools EI-GUN on goat was conducted in the Sumber Sekar Laboratory, Animal Husbandry Faculty, UB.  The methods of research were literature study, tool specification determination, designing EI-GUN, running test, semen evaluation passed EI-GUN and application on Goat. EI-GUN has seven important parts, which supports each other in this operating system. Those parts consist of stylet, servo, system controlled, insemination pump, connecting rod, battery, and holder. EI-GUN work system sucked the semen into insemination pump as much as 5 ml, and release the semen 0.25 ml appropriate standard of AI. It was applicable for 20 times AI. The results showed that the cell motility of spermatozoa ≥ 70% were still in ranging of Indonesian National Standard (SNI).   Keywords: artificial insemination, EI-GUN, fresh semen.

pubUniversity of Brawijaya
doi10.21776/ub.jtapro.2016.017.02.3
urlhttps://doaj.org/article/6396bfd8b92c4bc5b4e20a4ae9691faf
oafree_for_read
date2017-03-01