A comparative study of the diagnostic value of contrast-enhanced breast MR imaging and mammography on patients with BI-RADS 3-5 microcalcifications

OBJECTIVE: To retrospectively investigate the diagnostic value of breast MRI in patients with BI-RADS 3-5 microcalcifications in mammography. METHODS: Eighty-four patients with BI-RADS 3-5 microcalcifications on mammography underwent breast MR exams before surgical biopsy with a hookwire position un... Full description

Journal Title: PLoS ONE 01 January 2014, Vol.9(11), p.e111217
Main Author: Erni Li
Other Authors: Jing Li , Ying Song , Mei Xue , Chunwu Zhou
Format: Electronic Article Electronic Article
Language: English
Subjects:
ID: E-ISSN: 1932-6203 ; DOI: 10.1371/journal.pone.0111217
Zum Text:
SendSend as email Add to Book BagAdd to Book Bag
Staff View
recordid: doaj_soai_doaj_org_article_d34ee3f18fab48eb93f0ad40bdf32549
title: A comparative study of the diagnostic value of contrast-enhanced breast MR imaging and mammography on patients with BI-RADS 3-5 microcalcifications
format: Article
creator:
  • Erni Li
  • Jing Li
  • Ying Song
  • Mei Xue
  • Chunwu Zhou
subjects:
  • Sciences (General)
ispartof: PLoS ONE, 01 January 2014, Vol.9(11), p.e111217
description: OBJECTIVE: To retrospectively investigate the diagnostic value of breast MRI in patients with BI-RADS 3-5 microcalcifications in mammography. METHODS: Eighty-four patients with BI-RADS 3-5 microcalcifications on mammography underwent breast MR exams before surgical biopsy with a hookwire position under mammographic guidance. Two radiologists reviewed each lesion with BI-RADS by consensus. The diagnostic value of mammography and MRI was compared. RESULTS: Histopathological examination revealed 49 benign lesions and 42 malignant lesions. In the assessments of mammography, 21 lesions (23.1%) were assigned to category 3, 51 lesions (56.0%) to category 4, and 19 lesions (20.9%) to category 5. The area under the receiver operating characteristic(ROC) curve for mammography and MR assessment was 0.844, and 0.945, respectively (p
language: eng
source:
identifier: E-ISSN: 1932-6203 ; DOI: 10.1371/journal.pone.0111217
fulltext: fulltext_linktorsrc
issn:
  • 1932-6203
  • 19326203
url: Link


@attributes
ID708008818
RANK0.07
NO1
SEARCH_ENGINEprimo_central_multiple_fe
SEARCH_ENGINE_TYPEPrimo Central Search Engine
LOCALfalse
PrimoNMBib
record
control
sourcerecordidoai_doaj_org_article_d34ee3f18fab48eb93f0ad40bdf32549
sourceiddoaj_s
recordidTN_doaj_soai_doaj_org_article_d34ee3f18fab48eb93f0ad40bdf32549
sourcesystemOther
dbidDOA
pqid1620587372
galeid416969169
display
typearticle
titleA comparative study of the diagnostic value of contrast-enhanced breast MR imaging and mammography on patients with BI-RADS 3-5 microcalcifications
creatorErni Li ; Jing Li ; Ying Song ; Mei Xue ; Chunwu Zhou
ispartofPLoS ONE, 01 January 2014, Vol.9(11), p.e111217
identifierE-ISSN: 1932-6203 ; DOI: 10.1371/journal.pone.0111217
subjectSciences (General)
descriptionOBJECTIVE: To retrospectively investigate the diagnostic value of breast MRI in patients with BI-RADS 3-5 microcalcifications in mammography. METHODS: Eighty-four patients with BI-RADS 3-5 microcalcifications on mammography underwent breast MR exams before surgical biopsy with a hookwire position under mammographic guidance. Two radiologists reviewed each lesion with BI-RADS by consensus. The diagnostic value of mammography and MRI was compared. RESULTS: Histopathological examination revealed 49 benign lesions and 42 malignant lesions. In the assessments of mammography, 21 lesions (23.1%) were assigned to category 3, 51 lesions (56.0%) to category 4, and 19 lesions (20.9%) to category 5. The area under the receiver operating characteristic(ROC) curve for mammography and MR assessment was 0.844, and 0.945, respectively (p<0.05). In cases of category 3 microcalcifications, the specificity of mammography and MR was 100%, and 95.2% (p = 1.000), respectively. In cases of category 4 microcalcifications, the specificity, PPV and accuracy of mammography was 0%, 45.1% and 45.1%; whereas those for MR was 82.1% (p<0.05), 80.8% (P = 0.003) and 86.3% (p<0.05). All microcalcifications of category 5 were correctly diagnosed by mammography and MR. CONCLUSIONS: Breast MRI has the potential to significantly improve the diagnosis of category 4 microcalcifications on mammography. Among mammographic category 4 microcalcifications, about 82% of benign lesions can be degraded to BI-RADS 1∼3 by MRI. However for microcalcifications of category 3 and 5, MR exams do not show significant improvement over mammography.
languageeng
oafree_for_read
source
version7
lds50peer_reviewed
links
openurl$$Topenurl_article
openurlfulltext$$Topenurlfull_article
linktorsrc$$Uhttps://doaj.org/article/d34ee3f18fab48eb93f0ad40bdf32549$$EView_full_text_in_DOAJ
search
creatorcontrib
0Erni Li
1Jing Li
2Ying Song
3Mei Xue
4Chunwu Zhou
titleA comparative study of the diagnostic value of contrast-enhanced breast MR imaging and mammography on patients with BI-RADS 3-5 microcalcifications
description

OBJECTIVE: To retrospectively investigate the diagnostic value of breast MRI in patients with BI-RADS 3-5 microcalcifications in mammography. METHODS: Eighty-four patients with BI-RADS 3-5 microcalcifications on mammography underwent breast MR exams before surgical biopsy with a hookwire position under mammographic guidance. Two radiologists reviewed each lesion with BI-RADS by consensus. The diagnostic value of mammography and MRI was compared. RESULTS: Histopathological examination revealed 49 benign lesions and 42 malignant lesions. In the assessments of mammography, 21 lesions (23.1%) were assigned to category 3, 51 lesions (56.0%) to category 4, and 19 lesions (20.9%) to category 5. The area under the receiver operating characteristic(ROC) curve for mammography and MR assessment was 0.844, and 0.945, respectively (p<0.05). In cases of category 3 microcalcifications, the specificity of mammography and MR was 100%, and 95.2% (p = 1.000), respectively. In cases of category 4 microcalcifications, the specificity, PPV and accuracy of mammography was 0%, 45.1% and 45.1%; whereas those for MR was 82.1% (p<0.05), 80.8% (P = 0.003) and 86.3% (p<0.05). All microcalcifications of category 5 were correctly diagnosed by mammography and MR. CONCLUSIONS: Breast MRI has the potential to significantly improve the diagnosis of category 4 microcalcifications on mammography. Among mammographic category 4 microcalcifications, about 82% of benign lesions can be degraded to BI-RADS 1∼3 by MRI. However for microcalcifications of category 3 and 5, MR exams do not show significant improvement over mammography.

subjectSciences (General)
general
0English
1Public Library of Science (PLoS)
210.1371/journal.pone.0111217
3Directory of Open Access Journals (DOAJ)
sourceiddoaj_s
recordiddoaj_soai_doaj_org_article_d34ee3f18fab48eb93f0ad40bdf32549
issn
01932-6203
119326203
rsrctypearticle
creationdate2014
addtitlePLoS ONE
searchscope
0doaj_full
1doaj1
scope
0doaj_full
1doaj1
lsr45$$EView_full_text_in_DOAJ
tmp01Directory of Open Access Journals (DOAJ)
tmp02DOA
startdate20140101
enddate20140101
lsr40PLoS ONE, 01 January 2014, Vol.9 (11), p.e111217
doi10.1371/journal.pone.0111217
citationpf e111217 vol 9 issue 11
lsr30VSR-Enriched:[galeid, pages, pqid]
sort
titleA comparative study of the diagnostic value of contrast-enhanced breast MR imaging and mammography on patients with BI-RADS 3-5 microcalcifications
authorErni Li ; Jing Li ; Ying Song ; Mei Xue ; Chunwu Zhou
creationdate20140101
lso0120140101
facets
frbrgroupid7853363062736969419
frbrtype5
newrecords20190714
languageeng
topicSciences (General)
collectionDirectory of Open Access Journals (DOAJ)
prefilterarticles
rsrctypearticles
creatorcontrib
0Erni Li
1Jing Li
2Ying Song
3Mei Xue
4Chunwu Zhou
jtitlePLoS ONE
creationdate2014
toplevelpeer_reviewed
delivery
delcategoryRemote Search Resource
fulltextfulltext_linktorsrc
addata
au
0Erni Li
1Jing Li
2Ying Song
3Mei Xue
4Chunwu Zhou
atitleA comparative study of the diagnostic value of contrast-enhanced breast MR imaging and mammography on patients with BI-RADS 3-5 microcalcifications
jtitlePLoS ONE
risdate20140101
volume9
issue11
spagee111217
eissn1932-6203
formatjournal
genrearticle
ristypeJOUR
abstract

OBJECTIVE: To retrospectively investigate the diagnostic value of breast MRI in patients with BI-RADS 3-5 microcalcifications in mammography. METHODS: Eighty-four patients with BI-RADS 3-5 microcalcifications on mammography underwent breast MR exams before surgical biopsy with a hookwire position under mammographic guidance. Two radiologists reviewed each lesion with BI-RADS by consensus. The diagnostic value of mammography and MRI was compared. RESULTS: Histopathological examination revealed 49 benign lesions and 42 malignant lesions. In the assessments of mammography, 21 lesions (23.1%) were assigned to category 3, 51 lesions (56.0%) to category 4, and 19 lesions (20.9%) to category 5. The area under the receiver operating characteristic(ROC) curve for mammography and MR assessment was 0.844, and 0.945, respectively (p<0.05). In cases of category 3 microcalcifications, the specificity of mammography and MR was 100%, and 95.2% (p = 1.000), respectively. In cases of category 4 microcalcifications, the specificity, PPV and accuracy of mammography was 0%, 45.1% and 45.1%; whereas those for MR was 82.1% (p<0.05), 80.8% (P = 0.003) and 86.3% (p<0.05). All microcalcifications of category 5 were correctly diagnosed by mammography and MR. CONCLUSIONS: Breast MRI has the potential to significantly improve the diagnosis of category 4 microcalcifications on mammography. Among mammographic category 4 microcalcifications, about 82% of benign lesions can be degraded to BI-RADS 1∼3 by MRI. However for microcalcifications of category 3 and 5, MR exams do not show significant improvement over mammography.

pubPublic Library of Science (PLoS)
doi10.1371/journal.pone.0111217
urlhttps://doaj.org/article/d34ee3f18fab48eb93f0ad40bdf32549
lad01PLoS ONE
oafree_for_read
pagese111217
date2014-01-01