Development of a gamma-ray imager using a large area monolithic 4 × 4 mppc array for a future pet scanner

We report the development of a monolithic MPPC array, which consists of 3 × 3 mm 2 elements arranged as a 4 × 4 array manufactured by Hamamatsu applicable to next generation PET scanners. We show that the MPPC is suitable for time of flight PET applications by simple measurement using coincident bac... Full description

Journal Title: Journal of Instrumentation 2012, Vol.7(01), p.C01083
Main Author: T Nakamori
Format: Electronic Article Electronic Article
Language: English
Subjects:
ID: ISSN: ; E-ISSN: 1748-0221 ; DOI: 10.1088/1748-0221/7/01/C01083
Link: http://dx.doi.org/10.1088/1748-0221/7/01/C01083
Zum Text:
SendSend as email Add to Book BagAdd to Book Bag
Staff View
recordid: iop10.1088/1748-0221/7/01/C01083
title: Development of a gamma-ray imager using a large area monolithic 4 × 4 mppc array for a future pet scanner
format: Article
creator:
  • T Nakamori
subjects:
  • Gamma Rays
  • Detectors
  • Energy Resolution
  • Tomography
  • Sampling
  • Scanners
  • Positron Emission
  • Arrays
  • Instruments and Measurements (So)
ispartof: Journal of Instrumentation, 2012, Vol.7(01), p.C01083
description: We report the development of a monolithic MPPC array, which consists of 3 × 3 mm 2 elements arranged as a 4 × 4 array manufactured by Hamamatsu applicable to next generation PET scanners. We show that the MPPC is suitable for time of flight PET applications by simple measurement using coincident back-to-back 511 keV gamma rays. We demonstrated that the MPPC has much better timing resolution of 600 ps than the APD. We coupled the monolithic MPPC array with the Ce:LYSO and Pr:LuAG scintillator matrices as gamma-ray detectors. The energy resolutions were evaluated as 14 % with 662 keV gamma-rays and the Ce:LYSO achieved the best. We also used a resistor network readout circuit with some optimization. The averaged positional resolution is estimated as 0.27 mm in both x and y directions, while the energy resolution of each pixel was 9.9% for 662 keV gamma rays. Finally we applied the GHz class fast sampling waveform acquisition system to improve performance, and demonstrated efficient noise reduction by the clear detection of 22 keV gamma rays.
language: eng
source:
identifier: ISSN: ; E-ISSN: 1748-0221 ; DOI: 10.1088/1748-0221/7/01/C01083
fulltext: fulltext
issn:
  • 1748-0221
  • 17480221
url: Link


@attributes
ID273737382
RANK0.07
NO1
SEARCH_ENGINEprimo_central_multiple_fe
SEARCH_ENGINE_TYPEPrimo Central Search Engine
LOCALfalse
PrimoNMBib
record
control
sourcerecordid10.1088/1748-0221/7/01/C01083
sourceidiop
recordidTN_iop10.1088/1748-0221/7/01/C01083
sourcesystemPC
pqid1448705210
display
typearticle
titleDevelopment of a gamma-ray imager using a large area monolithic 4 × 4 mppc array for a future pet scanner
creatorT Nakamori
ispartofJournal of Instrumentation, 2012, Vol.7(01), p.C01083
identifier
descriptionWe report the development of a monolithic MPPC array, which consists of 3 × 3 mm 2 elements arranged as a 4 × 4 array manufactured by Hamamatsu applicable to next generation PET scanners. We show that the MPPC is suitable for time of flight PET applications by simple measurement using coincident back-to-back 511 keV gamma rays. We demonstrated that the MPPC has much better timing resolution of 600 ps than the APD. We coupled the monolithic MPPC array with the Ce:LYSO and Pr:LuAG scintillator matrices as gamma-ray detectors. The energy resolutions were evaluated as 14 % with 662 keV gamma-rays and the Ce:LYSO achieved the best. We also used a resistor network readout circuit with some optimization. The averaged positional resolution is estimated as 0.27 mm in both x and y directions, while the energy resolution of each pixel was 9.9% for 662 keV gamma rays. Finally we applied the GHz class fast sampling waveform acquisition system to improve performance, and demonstrated efficient noise reduction by the clear detection of 22 keV gamma rays.
languageeng
source
subjectGamma Rays ; Detectors ; Energy Resolution ; Tomography ; Sampling ; Scanners ; Positron Emission ; Arrays ; Instruments and Measurements (So);
version2
lds50peer_reviewed
links
openurl$$Topenurl_article
backlink$$Uhttp://dx.doi.org/10.1088/1748-0221/7/01/C01083$$EView_record_in_IOPscience
openurlfulltext$$Topenurlfull_article
search
creatorcontribT Nakamori
titleDevelopment of a gamma-ray imager using a large area monolithic 4 × 4 MPPC array for a future PET scanner
descriptionWe report the development of a monolithic MPPC array, which consists of 3 × 3 mm 2 elements arranged as a 4 × 4 array manufactured by Hamamatsu applicable to next generation PET scanners. We show that the MPPC is suitable for time of flight PET applications by simple measurement using coincident back-to-back 511 keV gamma rays. We demonstrated that the MPPC has much better timing resolution of 600 ps than the APD. We coupled the monolithic MPPC array with the Ce:LYSO and Pr:LuAG scintillator matrices as gamma-ray detectors. The energy resolutions were evaluated as 14 % with 662 keV gamma-rays and the Ce:LYSO achieved the best. We also used a resistor network readout circuit with some optimization. The averaged positional resolution is estimated as 0.27 mm in both x and y directions, while the energy resolution of each pixel was 9.9% for 662 keV gamma rays. Finally we applied the GHz class fast sampling waveform acquisition system to improve performance, and demonstrated efficient noise reduction by the clear detection of 22 keV gamma rays.
general
010.1088/1748-0221/7/01/C01083
1English
2IOPscience (IOP Publishing)
3Journal Of Instrumentation
sourceidiop
recordidiop10.1088/1748-0221/7/01/C01083
issn
01748-0221
117480221
rsrctypearticle
creationdate2012
recordtypearticle
addtitleJournal of Instrumentation
searchscope
0iop_rs
1iop
scope
0iop_rs
1iop
lsr30VSR-Enriched:[subject, pqid, pages, issue]
sort
titleDevelopment of a gamma-ray imager using a large area monolithic 4 × 4 mppc array for a future pet scanner
creationdate20120101
authorT Nakamori
facets
frbrgroupid8433436565636813932
frbrtype5
languageeng
creationdate2012
collectionIOPscience (Institute of Physics)
prefilterarticles
rsrctypearticles
creatorcontribT Nakamori
jtitleJournal Of Instrumentation
toplevelpeer_reviewed
delivery
delcategoryRemote Search Resource
fulltextfulltext
addata
auT Nakamori
atitleDevelopment of a gamma-ray imager using a large area monolithic 4 × 4 MPPC array for a future PET scanner
jtitleJournal of Instrumentation
risdate20120101
volume7
issue1
spageC01083
epageC01083
eissn1748-0221
formatjournal
genrearticle
ristypeJOUR
abstractWe report the development of a monolithic MPPC array, which consists of 3 × 3 mm 2 elements arranged as a 4 × 4 array manufactured by Hamamatsu applicable to next generation PET scanners. We show that the MPPC is suitable for time of flight PET applications by simple measurement using coincident back-to-back 511 keV gamma rays. We demonstrated that the MPPC has much better timing resolution of 600 ps than the APD. We coupled the monolithic MPPC array with the Ce:LYSO and Pr:LuAG scintillator matrices as gamma-ray detectors. The energy resolutions were evaluated as 14 % with 662 keV gamma-rays and the Ce:LYSO achieved the best. We also used a resistor network readout circuit with some optimization. The averaged positional resolution is estimated as 0.27 mm in both x and y directions, while the energy resolution of each pixel was 9.9% for 662 keV gamma rays. Finally we applied the GHz class fast sampling waveform acquisition system to improve performance, and demonstrated efficient noise reduction by the clear detection of 22 keV gamma rays.
doi10.1088/1748-0221/7/01/C01083
pages1-13
date2012-01-01