schliessen

Filtern

 

Bibliotheken

Low temperature fatigue tests of reinforced straight thread sleeve connections of a high speed railway station in Northern China

The low temperature constant amplitude fatigue tests of reinforced straight thread sleeve connections in rail floor structure of a high speed railway station in Northern China were carried out to verify their fatigue resistance under dynamic loadings, in order to control the construction period, and... Full description

Journal Title: Journal of Shenyang Jianzhu University (Natural Science) Nov 2012, Vol.28(6), pp.961-966
Main Author: Wang, Yuanqing
Other Authors: Zhou, Hui , Chen, Yueping , Zhao, Xinyue , Shi, Yongjiu
Format: Electronic Article Electronic Article
Language: chi
Subjects:
Quelle: © ProQuest LLC All rights reserved
ID: ISSN: 2095-1922
Link: http://search.proquest.com/docview/1692383334/?pq-origsite=primo
Zum Text:
SendSend as email Add to Book BagAdd to Book Bag
Staff View
recordid: proquest1692383334
title: Low temperature fatigue tests of reinforced straight thread sleeve connections of a high speed railway station in Northern China
format: Article
creator:
  • Wang, Yuanqing
  • Zhou, Hui
  • Chen, Yueping
  • Zhao, Xinyue
  • Shi, Yongjiu
subjects:
  • Railway Stations
  • Fatigue Strength
  • Rails
  • Sleeves
  • Fatigue Tests
  • Loads (Forces)
  • China
  • Joints
  • Architectural Engineering, Structural Design, and Properties (General) (CE)
ispartof: Journal of Shenyang Jianzhu University (Natural Science), Nov 2012, Vol.28(6), pp.961-966
description: The low temperature constant amplitude fatigue tests of reinforced straight thread sleeve connections in rail floor structure of a high speed railway station in Northern China were carried out to verify their fatigue resistance under dynamic loadings, in order to control the construction period, and to ensure the quality, safety and reliability of the structure. A total of 13 connection specimens fabricated from HRB400 steel reinforced bars with diameters of 28 mm and 32 mm were prepared. The fatigue tests were controlled by constant stress range of 100 MPa and a low temperature controlling equipment was specially designed to achieve conditions with low temperatures of -10 degree C and -20 degree C. Among the thirteen tested specimens, four failed due to fatigue before 2.0 million cycles and the remaining met the fatigue resistance requirement of enduring 2 million cycles. The test results indicate that the reinforced straight thread sleeve connections satisfy the fatigue performance at low temperatures required by the engineering project according to "Technical Specification for Mechanical Splicing of Steel Reinforcing Bars(JGJ 107-2010)". The present study provides an experimental basis for applications of reinforced straight thread sleeve connections in rail floor structures subjected to dynamic train loadings.
language: chi
source: © ProQuest LLC All rights reserved
identifier: ISSN: 2095-1922
fulltext: no_fulltext
issn:
  • 20951922
  • 2095-1922
url: Link


@attributes
ID1001444675
RANK0.07
NO1
SEARCH_ENGINEprimo_central_multiple_fe
SEARCH_ENGINE_TYPEPrimo Central Search Engine
LOCALfalse
PrimoNMBib
record
control
sourcerecordid1692383334
sourceidproquest
recordidTN_proquest1692383334
sourcesystemOther
pqid1692383334
display
typearticle
titleLow temperature fatigue tests of reinforced straight thread sleeve connections of a high speed railway station in Northern China
creatorWang, Yuanqing ; Zhou, Hui ; Chen, Yueping ; Zhao, Xinyue ; Shi, Yongjiu
contributorWang, Yuanqing (correspondence author)
ispartofJournal of Shenyang Jianzhu University (Natural Science), Nov 2012, Vol.28(6), pp.961-966
identifierISSN: 2095-1922
subjectRailway Stations ; Fatigue Strength ; Rails ; Sleeves ; Fatigue Tests ; Loads (Forces) ; China ; Joints ; Architectural Engineering, Structural Design, and Properties (General) (CE)
descriptionThe low temperature constant amplitude fatigue tests of reinforced straight thread sleeve connections in rail floor structure of a high speed railway station in Northern China were carried out to verify their fatigue resistance under dynamic loadings, in order to control the construction period, and to ensure the quality, safety and reliability of the structure. A total of 13 connection specimens fabricated from HRB400 steel reinforced bars with diameters of 28 mm and 32 mm were prepared. The fatigue tests were controlled by constant stress range of 100 MPa and a low temperature controlling equipment was specially designed to achieve conditions with low temperatures of -10 degree C and -20 degree C. Among the thirteen tested specimens, four failed due to fatigue before 2.0 million cycles and the remaining met the fatigue resistance requirement of enduring 2 million cycles. The test results indicate that the reinforced straight thread sleeve connections satisfy the fatigue performance at low temperatures required by the engineering project according to "Technical Specification for Mechanical Splicing of Steel Reinforcing Bars(JGJ 107-2010)". The present study provides an experimental basis for applications of reinforced straight thread sleeve connections in rail floor structures subjected to dynamic train loadings.
languagechi
source
0© ProQuest LLC All rights reserved
1Civil Engineering Abstracts
2Engineering Research Database
3Technology Research Database
4ProQuest Engineering Collection
5ProQuest Technology Collection
6ProQuest SciTech Collection
7Materials Science & Engineering Database
8SciTech Premium Collection
9Technology Collection
lds50peer_reviewed
links
openurl$$Topenurl_article
openurlfulltext$$Topenurlfull_article
backlink$$Uhttp://search.proquest.com/docview/1692383334/?pq-origsite=primo$$EView_record_in_ProQuest_(subscribers_only)
search
creatorcontrib
0Wang, Yuanqing
1Zhou, Hui
2Chen, Yueping
3Zhao, Xinyue
4Shi, Yongjiu
titleLow temperature fatigue tests of reinforced straight thread sleeve connections of a high speed railway station in Northern China
descriptionThe low temperature constant amplitude fatigue tests of reinforced straight thread sleeve connections in rail floor structure of a high speed railway station in Northern China were carried out to verify their fatigue resistance under dynamic loadings, in order to control the construction period, and to ensure the quality, safety and reliability of the structure. A total of 13 connection specimens fabricated from HRB400 steel reinforced bars with diameters of 28 mm and 32 mm were prepared. The fatigue tests were controlled by constant stress range of 100 MPa and a low temperature controlling equipment was specially designed to achieve conditions with low temperatures of -10 degree C and -20 degree C. Among the thirteen tested specimens, four failed due to fatigue before 2.0 million cycles and the remaining met the fatigue resistance requirement of enduring 2 million cycles. The test results indicate that the reinforced straight thread sleeve connections satisfy the fatigue performance at low temperatures required by the engineering project according to "Technical Specification for Mechanical Splicing of Steel Reinforcing Bars(JGJ 107-2010)". The present study provides an experimental basis for applications of reinforced straight thread sleeve connections in rail floor structures subjected to dynamic train loadings.
subject
0Railway Stations
1Fatigue Strength
2Rails
3Sleeves
4Fatigue Tests
5Loads (Forces)
6China
7Joints
8Architectural Engineering, Structural Design, and Properties (General) (CE)
920
general
0Chinese
1Civil Engineering Abstracts
2Engineering Research Database
3Technology Research Database
4ProQuest Engineering Collection
5ProQuest Technology Collection
6ProQuest SciTech Collection
7Materials Science & Engineering Database
8SciTech Premium Collection
9Technology Collection
sourceidproquest
recordidproquest1692383334
issn
020951922
12095-1922
rsrctypearticle
creationdate2012
addtitleJournal of Shenyang Jianzhu University (Natural Science)
searchscope
01007450
11007944
210000013
310000015
410000022
510000041
610000053
710000120
810000203
910000209
1010000250
1110000260
1210000265
13proquest
scope
01007450
11007944
210000013
310000015
410000022
510000041
610000053
710000120
810000203
910000209
1010000250
1110000260
1210000265
13proquest
lsr43
01007450false
11007944false
210000013false
310000015false
410000022false
510000041false
610000053false
710000120false
810000203false
910000209false
1010000250false
1110000260false
1210000265false
contributorWang, Yuanqing
startdate20121101
enddate20121101
citationpf 961 pt 966 vol 28 issue 6
sort
titleLow temperature fatigue tests of reinforced straight thread sleeve connections of a high speed railway station in Northern China
authorWang, Yuanqing ; Zhou, Hui ; Chen, Yueping ; Zhao, Xinyue ; Shi, Yongjiu
creationdate20121101
lso0120121101
facets
frbrgroupid4574219193757088345
frbrtype6
languagechi
creationdate2012
topic
0Railway Stations
1Fatigue Strength
2Rails
3Sleeves
4Fatigue Tests
5Loads (Forces)
6China
7Joints
8Architectural Engineering, Structural Design, and Properties (General) (CE)
collection
0Civil Engineering Abstracts
1Engineering Research Database
2Technology Research Database
3ProQuest Engineering Collection
4ProQuest Technology Collection
5ProQuest SciTech Collection
6Materials Science & Engineering Database
7SciTech Premium Collection
8Technology Collection
prefilterarticles
rsrctypearticles
creatorcontrib
0Wang, Yuanqing
1Zhou, Hui
2Chen, Yueping
3Zhao, Xinyue
4Shi, Yongjiu
jtitleJournal of Shenyang Jianzhu University (Natural Science)
toplevelpeer_reviewed
delivery
delcategoryRemote Search Resource
fulltextno_fulltext
addata
aulast
0Wang
1Zhou
2Chen
3Zhao
4Shi
aufirst
0Yuanqing
1Hui
2Yueping
3Xinyue
4Yongjiu
au
0Wang, Yuanqing
1Zhou, Hui
2Chen, Yueping
3Zhao, Xinyue
4Shi, Yongjiu
addauWang, Yuanqing
atitleLow temperature fatigue tests of reinforced straight thread sleeve connections of a high speed railway station in Northern China
jtitleJournal of Shenyang Jianzhu University (Natural Science)
risdate20121101
volume28
issue6
spage961
epage966
pages961-966
issn2095-1922
formatjournal
genrearticle
ristypeJOUR
abstractThe low temperature constant amplitude fatigue tests of reinforced straight thread sleeve connections in rail floor structure of a high speed railway station in Northern China were carried out to verify their fatigue resistance under dynamic loadings, in order to control the construction period, and to ensure the quality, safety and reliability of the structure. A total of 13 connection specimens fabricated from HRB400 steel reinforced bars with diameters of 28 mm and 32 mm were prepared. The fatigue tests were controlled by constant stress range of 100 MPa and a low temperature controlling equipment was specially designed to achieve conditions with low temperatures of -10 degree C and -20 degree C. Among the thirteen tested specimens, four failed due to fatigue before 2.0 million cycles and the remaining met the fatigue resistance requirement of enduring 2 million cycles. The test results indicate that the reinforced straight thread sleeve connections satisfy the fatigue performance at low temperatures required by the engineering project according to "Technical Specification for Mechanical Splicing of Steel Reinforcing Bars(JGJ 107-2010)". The present study provides an experimental basis for applications of reinforced straight thread sleeve connections in rail floor structures subjected to dynamic train loadings.
urlhttp://search.proquest.com/docview/1692383334/
date2012-11-01