We develop a novel method for Western blot based on microfluidics, incorporating the internal molecular weight marker, loading control, and antibody titration in the same protocol. Compared with the conventional method which could detect only one protein, the microfluidic Western blot could analyze... Full description

Journal Title: Analytical chemistry May 15, 2010, Vol.82(10), pp.3974-3976
Main Author: Pan, Wenying
Other Authors: Chen, Wei , Jiang, Xingyu
Format: Electronic Article Electronic Article
Language: English
Subjects:
ID: E-ISSN: 1520-6882 ; DOI: 1520-6882 ; DOI: 10.1021/ac1000493
Link: http://search.proquest.com/docview/733521133/?pq-origsite=primo
Zum Text:
SendSend as email Add to Book BagAdd to Book Bag
Staff View
recordid: proquest733521133
title: Microfluidic Western blot.
format: Article
creator:
  • Pan, Wenying
  • Chen, Wei
  • Jiang, Xingyu
subjects:
  • Antibodies–Analysis
  • Biomarkers–Methods
  • Blotting, Western–Methods
  • Microfluidics–Analysis
  • Proteins–Analysis
  • Antibodies
  • Biomarkers
  • Proteins
ispartof: Analytical chemistry, May 15, 2010, Vol.82(10), pp.3974-3976
description: We develop a novel method for Western blot based on microfluidics, incorporating the internal molecular weight marker, loading control, and antibody titration in the same protocol. Compared with the conventional method which could detect only one protein, the microfluidic Western blot could analyze at least 10 proteins simultaneously from a single sample, and it requires only about 1% of the amount of antibody used in conventional Western blot. 10.1021/ac1000493
language: eng
source:
identifier: E-ISSN: 1520-6882 ; DOI: 1520-6882 ; DOI: 10.1021/ac1000493
fulltext: no_fulltext
issn:
  • 15206882
  • 1520-6882
url: Link


@attributes
ID1590461983
RANK0.07
NO1
SEARCH_ENGINEprimo_central_multiple_fe
SEARCH_ENGINE_TYPEPrimo Central Search Engine
LOCALfalse
PrimoNMBib
record
control
sourcerecordid733521133
sourceidproquest
recordidTN_proquest733521133
sourcesystemOther
pqid733521133
galeid227797353
display
typearticle
titleMicrofluidic Western blot.
creatorPan, Wenying ; Chen, Wei ; Jiang, Xingyu
contributorPan, Wenying (correspondence author) ; Pan, Wenying (record owner)
ispartofAnalytical chemistry, May 15, 2010, Vol.82(10), pp.3974-3976
identifier
subjectAntibodies–Analysis ; Biomarkers–Methods ; Blotting, Western–Methods ; Microfluidics–Analysis ; Proteins–Analysis ; Antibodies ; Biomarkers ; Proteins
languageeng
source
descriptionWe develop a novel method for Western blot based on microfluidics, incorporating the internal molecular weight marker, loading control, and antibody titration in the same protocol. Compared with the conventional method which could detect only one protein, the microfluidic Western blot could analyze at least 10 proteins simultaneously from a single sample, and it requires only about 1% of the amount of antibody used in conventional Western blot. 10.1021/ac1000493
version4
lds50peer_reviewed
links
openurl$$Topenurl_article
openurlfulltext$$Topenurlfull_article
backlink$$Uhttp://search.proquest.com/docview/733521133/?pq-origsite=primo$$EView_record_in_ProQuest_(subscribers_only)
search
creatorcontrib
0Pan, Wenying
1Chen, Wei
2Jiang, Xingyu
titleMicrofluidic Western blot.
subject
0Antibodies–Analysis
1Biomarkers–Methods
2Blotting, Western–Methods
3Microfluidics–Analysis
4Proteins–Analysis
5Antibodies
6Biomarkers
7Proteins
general
0English
11520-6882
210.1021/ac1000493
3MEDLINE (ProQuest)
4ProQuest Biological Science Collection
5ProQuest Natural Science Collection
6ProQuest SciTech Collection
7Biological Science Database
8Natural Science Collection
9SciTech Premium Collection
10Health Research Premium Collection
11Health Research Premium Collection (Alumni edition)
sourceidproquest
recordidproquest733521133
issn
015206882
11520-6882
rsrctypearticle
creationdate2010
addtitleAnalytical chemistry
searchscope
01007527
11007944
210000004
310000038
410000050
510000120
610000159
710000238
810000253
910000260
1010000270
1110000271
1210000302
13proquest
scope
01007527
11007944
210000004
310000038
410000050
510000120
610000159
710000238
810000253
910000260
1010000270
1110000271
1210000302
13proquest
lsr43
01007527false
11007944false
210000004false
310000038false
410000050false
510000120false
610000159false
710000238false
810000253false
910000260false
1010000270false
1110000271false
1210000302false
contributorPan, Wenying
startdate20100515
enddate20100515
citationpf 3974 pt 3976 vol 82 issue 10
lsr30VSR-Enriched:[description, pqid, issn, galeid]
sort
titleMicrofluidic Western blot.
authorPan, Wenying ; Chen, Wei ; Jiang, Xingyu
creationdate20100515
lso0120100515
facets
frbrgroupid8974136429913933371
frbrtype5
newrecords20181218
languageeng
creationdate2010
topic
0Antibodies–Analysis
1Biomarkers–Methods
2Blotting, Western–Methods
3Microfluidics–Analysis
4Proteins–Analysis
5Antibodies
6Biomarkers
7Proteins
collection
0MEDLINE (ProQuest)
1ProQuest Biological Science Collection
2ProQuest Natural Science Collection
3ProQuest SciTech Collection
4Biological Science Database
5Natural Science Collection
6SciTech Premium Collection
7Health Research Premium Collection
8Health Research Premium Collection (Alumni edition)
prefilterarticles
rsrctypearticles
creatorcontrib
0Pan, Wenying
1Chen, Wei
2Jiang, Xingyu
jtitleAnalytical chemistry
toplevelpeer_reviewed
delivery
delcategoryRemote Search Resource
fulltextno_fulltext
addata
aulast
0Pan
1Chen
2Jiang
aufirst
0Wenying
1Wei
2Xingyu
au
0Pan, Wenying
1Chen, Wei
2Jiang, Xingyu
addauPan, Wenying
atitleMicrofluidic Western blot.
jtitleAnalytical chemistry
risdate20100515
volume82
issue10
spage3974
epage3976
pages3974-3976
eissn1520-6882
formatjournal
genrearticle
ristypeJOUR
doi10.1021/ac1000493
urlhttp://search.proquest.com/docview/733521133/
issn00032700
date2010-05-15