schliessen

Filtern

 

Bibliotheken

Combination of Aortic Stent-graft and Arterial Embolization for Ruptured Bronchial Artery Aneurysm

Bronchial artery aneurysm (BAA) is a rare condition. Rupture of BAA can cause a critical hemorrhage. We report one case of ruptured bronchial artery aneurysm mimicking a clinical picture of aortic dissection with right hemothorax. The patient was treated with combination of aortic stent-graft and ar... Full description

Journal Title: The Annals of Thoracic Surgery
Main Author: Hu, Chuan-Xian
Other Authors: Huang, Su , Xu, Zhi-Wei , Chen, Wei , Huang, Jia-Sheng , Fu, Zhi
Format: Electronic Article Electronic Article
Language: English
Subjects:
ID: ISSN: 0003-4975 ; DOI: 10.1016/j.athoracsur.2011.02.082
Link: http://dx.doi.org/10.1016/j.athoracsur.2011.02.082
Zum Text:
SendSend as email Add to Book BagAdd to Book Bag
Staff View
recordid: sciversesciencedirect_elsevierS0003-4975(11)00537-6
title: Combination of Aortic Stent-graft and Arterial Embolization for Ruptured Bronchial Artery Aneurysm
format: Article
creator:
  • Hu, Chuan-Xian
  • Huang, Su
  • Xu, Zhi-Wei
  • Chen, Wei
  • Huang, Jia-Sheng
  • Fu, Zhi
subjects:
  • Bronchial Artery Aneurysm
  • Embolization
  • Stent-Graft
ispartof: The Annals of Thoracic Surgery
description: Bronchial artery aneurysm (BAA) is a rare condition. Rupture of BAA can cause a critical hemorrhage. We report one case of ruptured bronchial artery aneurysm mimicking a clinical picture of aortic dissection with right hemothorax. The patient was treated with combination of aortic stent-graft and arterial embolization. Recovery was uneventful and the follow up result in one year was well. Combination treatment is feasible and accurate for ruptured bronchial artery aneurysm. The present study is the fifth reported case in which an aortic stent- graft has been used for BAA.
language: eng
source:
identifier: ISSN: 0003-4975 ; DOI: 10.1016/j.athoracsur.2011.02.082
fulltext: fulltext
issn:
  • 00034975
  • 0003-4975
url: Link


@attributes
ID1812413904
RANK0.06999999
NO1
SEARCH_ENGINEprimo_central_multiple_fe
SEARCH_ENGINE_TYPEPrimo Central Search Engine
LOCALfalse
PrimoNMBib
record
control
sourcerecordidS0003-4975(11)00537-6
sourceidsciversesciencedirect_elsevier
recordidTN_sciversesciencedirect_elsevierS0003-4975(11)00537-6
sourcesystemOther
pqid880714554
galeid265538759
display
typearticle
titleCombination of Aortic Stent-graft and Arterial Embolization for Ruptured Bronchial Artery Aneurysm
creatorHu, Chuan-Xian ; Huang, Su ; Xu, Zhi-Wei ; Chen, Wei ; Huang, Jia-Sheng ; Fu, Zhi
ispartofThe Annals of Thoracic Surgery
identifierISSN: 0003-4975 ; DOI: 10.1016/j.athoracsur.2011.02.082
subjectBronchial Artery Aneurysm ; Embolization ; Stent-Graft
descriptionBronchial artery aneurysm (BAA) is a rare condition. Rupture of BAA can cause a critical hemorrhage. We report one case of ruptured bronchial artery aneurysm mimicking a clinical picture of aortic dissection with right hemothorax. The patient was treated with combination of aortic stent-graft and arterial embolization. Recovery was uneventful and the follow up result in one year was well. Combination treatment is feasible and accurate for ruptured bronchial artery aneurysm. The present study is the fifth reported case in which an aortic stent- graft has been used for BAA.
languageeng
source
version6
lds50peer_reviewed
links
openurl$$Topenurl_article
backlink$$Uhttp://dx.doi.org/10.1016/j.athoracsur.2011.02.082$$EView_record_in_ScienceDirect
openurlfulltext$$Topenurlfull_article
search
creatorcontrib
0Hu, Chuan-Xian
1Huang, Su
2Xu, Zhi-Wei
3Chen, Wei
4Huang, Jia-Sheng
5Fu, Zhi
titleCombination of Aortic Stent-graft and Arterial Embolization for Ruptured Bronchial Artery Aneurysm
descriptionBronchial artery aneurysm (BAA) is a rare condition. Rupture of BAA can cause a critical hemorrhage. We report one case of ruptured bronchial artery aneurysm mimicking a clinical picture of aortic dissection with right hemothorax. The patient was treated with combination of aortic stent-graft and arterial embolization. Recovery was uneventful and the follow up result in one year was well. Combination treatment is feasible and accurate for ruptured bronchial artery aneurysm. The present study is the fifth reported case in which an aortic stent- graft has been used for BAA.
subject
0Bronchial Artery Aneurysm
1Embolization
2Stent-Graft
general
0English
1Elsevier Inc.
210.1016/j.athoracsur.2011.02.082
3ScienceDirect (Elsevier B.V.)
4ScienceDirect Journals (Elsevier)
sourceidsciversesciencedirect_elsevier
recordidsciversesciencedirect_elsevierS0003-4975(11)00537-6
issn
000034975
10003-4975
rsrctypearticle
creationdate2011
addtitleThe Annals of Thoracic Surgery
searchscope
0sciversesciencedirect_elsevier
1elsevier_sciencedirect
scope
0sciversesciencedirect_elsevier
1elsevier_sciencedirect
startdate20110101
enddate20111231
lsr30VSR-Enriched:[pqid, eissn, pages, galeid, vol, issue]
sort
titleCombination of Aortic Stent-graft and Arterial Embolization for Ruptured Bronchial Artery Aneurysm
authorHu, Chuan-Xian ; Huang, Su ; Xu, Zhi-Wei ; Chen, Wei ; Huang, Jia-Sheng ; Fu, Zhi
creationdate20110000
lso0120110000
facets
frbrgroupid4711307842980092587
frbrtype5
languageeng
creationdate2011
topic
0Bronchial Artery Aneurysm
1Embolization
2Stent-Graft
collectionScienceDirect Journals (Elsevier)
prefilterarticles
rsrctypearticles
creatorcontrib
0Hu, Chuan-Xian
1Huang, Su
2Xu, Zhi-Wei
3Chen, Wei
4Huang, Jia-Sheng
5Fu, Zhi
jtitleAnnals of Thoracic Surgery
toplevelpeer_reviewed
delivery
delcategoryRemote Search Resource
fulltextfulltext
addata
aulast
0Hu
1Huang
2Xu
3Chen
4Fu
aufirstChuan-Xian
au
0Hu, Chuan-Xian
1Huang, Su
2Xu, Zhi-Wei
3Chen, Wei
4Huang, Jia-Sheng
5Fu, Zhi
atitleCombination of Aortic Stent-graft and Arterial Embolization for Ruptured Bronchial Artery Aneurysm
jtitleThe Annals of Thoracic Surgery
date2011
risdate2011
issn0003-4975
formatjournal
genrearticle
ristypeJOUR
abstractBronchial artery aneurysm (BAA) is a rare condition. Rupture of BAA can cause a critical hemorrhage. We report one case of ruptured bronchial artery aneurysm mimicking a clinical picture of aortic dissection with right hemothorax. The patient was treated with combination of aortic stent-graft and arterial embolization. Recovery was uneventful and the follow up result in one year was well. Combination treatment is feasible and accurate for ruptured bronchial artery aneurysm. The present study is the fifth reported case in which an aortic stent- graft has been used for BAA.
pubElsevier Inc.
doi10.1016/j.athoracsur.2011.02.082
pagese19-21
volume92
issue2
eissn15526259