Combined gadoxetic acid and gadofosveset enhanced liver MRI: A feasibility and parameter optimization study

Byline: Peter Bannas, Utaroh Motosugi, Diego Hernando, Mahdi Salmani Rahimi, James H. Holmes, Scott B. Reeder Keywords: gadoxetic acid; gadofosveset trisodium; liver; MRI; hepatobiliary imaging Purpose Demonstration of feasibility and protocol optimization for the combined use of gadofosveset trisod... Full description

Journal Title: Magnetic Resonance in Medicine January 2016, Vol.75(1), pp.318-328
Main Author: Bannas, Peter
Other Authors: Motosugi, Utaroh , Hernando, Diego , Rahimi, Mahdi Salmani , Holmes, James H. , Reeder, Scott B.
Format: Electronic Article Electronic Article
Language:
Subjects:
Mri
ID: ISSN: 0740-3194 ; E-ISSN: 1522-2594 ; DOI: 10.1002/mrm.25554
Zum Text:
SendSend as email Add to Book BagAdd to Book Bag
Staff View
recordid: wj10.1002/mrm.25554
title: Combined gadoxetic acid and gadofosveset enhanced liver MRI: A feasibility and parameter optimization study
format: Article
creator:
  • Bannas, Peter
  • Motosugi, Utaroh
  • Hernando, Diego
  • Rahimi, Mahdi Salmani
  • Holmes, James H.
  • Reeder, Scott B.
subjects:
  • Gadoxetic Acid
  • Gadofosveset Trisodium
  • Liver
  • Mri
  • Hepatobiliary Imaging
ispartof: Magnetic Resonance in Medicine, January 2016, Vol.75(1), pp.318-328
description: Byline: Peter Bannas, Utaroh Motosugi, Diego Hernando, Mahdi Salmani Rahimi, James H. Holmes, Scott B. Reeder Keywords: gadoxetic acid; gadofosveset trisodium; liver; MRI; hepatobiliary imaging Purpose Demonstration of feasibility and protocol optimization for the combined use of gadofosveset trisodium with gadoxetic acid for delayed T1-weighted liver MRI. Methods Eleven healthy volunteers underwent hepatobiliary phase imaging at 3 Tesla (T) using gadoxetic acid. Multiple breathheld T1-weighted three-dimensional spoiled gradient echo sequences were performed at varying flip angles before and after injection of gadofosveset. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured to determine optimal T1-weighting. Examples of three patients with focal liver lesions were acquired. Results The addition of gadofosveset to the hepatobiliary phase of gadoxetic acid renders vessels isointense to liver tissue at low flip angles due to increased vessel SNR (P
language:
source:
identifier: ISSN: 0740-3194 ; E-ISSN: 1522-2594 ; DOI: 10.1002/mrm.25554
fulltext: fulltext
issn:
  • 0740-3194
  • 07403194
  • 1522-2594
  • 15222594
url: Link


@attributes
ID424452768
RANK0.07
NO1
SEARCH_ENGINEprimo_central_multiple_fe
SEARCH_ENGINE_TYPEPrimo Central Search Engine
LOCALfalse
PrimoNMBib
record
control
sourcerecordid10.1002/mrm.25554
sourceidwj
recordidTN_wj10.1002/mrm.25554
sourcesystemPC
pqid1757581711
galeid440016255
display
typearticle
titleCombined gadoxetic acid and gadofosveset enhanced liver MRI: A feasibility and parameter optimization study
creatorBannas, Peter ; Motosugi, Utaroh ; Hernando, Diego ; Rahimi, Mahdi Salmani ; Holmes, James H. ; Reeder, Scott B.
ispartofMagnetic Resonance in Medicine, January 2016, Vol.75(1), pp.318-328
identifier
subjectGadoxetic Acid ; Gadofosveset Trisodium ; Liver ; Mri ; Hepatobiliary Imaging
source
descriptionByline: Peter Bannas, Utaroh Motosugi, Diego Hernando, Mahdi Salmani Rahimi, James H. Holmes, Scott B. Reeder Keywords: gadoxetic acid; gadofosveset trisodium; liver; MRI; hepatobiliary imaging Purpose Demonstration of feasibility and protocol optimization for the combined use of gadofosveset trisodium with gadoxetic acid for delayed T1-weighted liver MRI. Methods Eleven healthy volunteers underwent hepatobiliary phase imaging at 3 Tesla (T) using gadoxetic acid. Multiple breathheld T1-weighted three-dimensional spoiled gradient echo sequences were performed at varying flip angles before and after injection of gadofosveset. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured to determine optimal T1-weighting. Examples of three patients with focal liver lesions were acquired. Results The addition of gadofosveset to the hepatobiliary phase of gadoxetic acid renders vessels isointense to liver tissue at low flip angles due to increased vessel SNR (P<0.001). The lowest CNR of liver relative to portal vein (CNR=15; 95% confidence interval [CI]: -14-44) was observed at a 10A* flip angle. The highest CNR of liver relative to muscle (CNR=214; 95% CI: 191-237) was observed at a 20A* flip angle. The combined enhancement leads to homogenously enhanced liver tissue and liver vasculature. Cysts were detected in three volunteers and metastases were detected in two patients. In these anecdotal cases the cysts and metastases stood out as conspicuous focal hypointensities on combined gadoxetic acid and gadofosveset enhanced images. Conclusion Combined gadoxetic acid and gadofosveset enhanced liver MRI is feasible, with low flip angles minimizing contrast between vessels and liver. Further clinical studies are needed to confirm that low flip angles provide an optimal combination of sensitivity and specificity for lesion detection in patients. Magn Reson Med 75:318-328, 2016. [c] 2015 Wiley Periodicals, Inc.
version9
lds50peer_reviewed
links
openurl$$Topenurl_article
openurlfulltext$$Topenurlfull_article
search
creatorcontrib
0Bannas, Peter
1Motosugi, Utaroh
2Hernando, Diego
3Rahimi, Mahdi Salmani
4Holmes, James H.
5Reeder, Scott B.
titleCombined gadoxetic acid and gadofosveset enhanced liver MRI: A feasibility and parameter optimization study
subject
0Gadoxetic Acid
1Gadofosveset Trisodium
2Liver
3Mri
4Hepatobiliary Imaging
general
010.1002/mrm.25554
1Wiley Online Library
sourceidwj
recordidwj10.1002/mrm.25554
issn
00740-3194
107403194
21522-2594
315222594
rsrctypearticle
creationdate2016
addtitle
0Magnetic Resonance in Medicine
1Magn. Reson. Med.
searchscope
0wj
1wiley
scope
0wj
1wiley
lsr30VSR-Enriched:[description, pqid, galeid, pages]
sort
titleCombined gadoxetic acid and gadofosveset enhanced liver MRI: A feasibility and parameter optimization study
authorBannas, Peter ; Motosugi, Utaroh ; Hernando, Diego ; Rahimi, Mahdi Salmani ; Holmes, James H. ; Reeder, Scott B.
creationdate20160100
facets
frbrgroupid6936957917414948807
frbrtype5
creationdate2016
topic
0Gadoxetic Acid
1Gadofosveset Trisodium
2Liver
3Mri
4Hepatobiliary Imaging
collectionWiley Online Library
prefilterarticles
rsrctypearticles
creatorcontrib
0Bannas, Peter
1Motosugi, Utaroh
2Hernando, Diego
3Rahimi, Mahdi Salmani
4Holmes, James H.
5Reeder, Scott B.
jtitleMagnetic Resonance in Medicine
toplevelpeer_reviewed
delivery
delcategoryRemote Search Resource
fulltextfulltext
addata
aulast
0Bannas
1Motosugi
2Hernando
3Rahimi
4Holmes
5Reeder
aufirst
0Peter
1Utaroh
2Diego
3Mahdi Salmani
4James H.
5Scott B.
au
0Bannas, Peter
1Motosugi, Utaroh
2Hernando, Diego
3Rahimi, Mahdi Salmani
4Holmes, James H.
5Reeder, Scott B.
atitleCombined gadoxetic acid and gadofosveset enhanced liver MRI: A feasibility and parameter optimization study
jtitleMagnetic Resonance in Medicine
risdate201601
volume75
issue1
spage318
epage328
issn0740-3194
eissn1522-2594
genrearticle
ristypeJOUR
doi10.1002/mrm.25554
pages318-328
date2016-01